tyco play search access newsIcon longArrow logOut shopCart icon_stopCarousel icon_playCarousel telecom industry defense prodFamily phone envelope pdfIcon dolarIcon arrowRight printIcon docIcon teldor menuIcon contact zoom globe logInIcon loggedUserIcon envelope facebook twiter linkdin arrow close sliderBg menuArr modalArr

Overview of Teldor's Offshore Instrumentation & Control Cables

Home / Overview of Teldor's Offshore Instrumentation & Control Cables




Teldor Cables & Systems, established in 1966, designs and manufactures over 6,500 cables for a wide range of applications including both onshore and offshore installations. Teldor supplies quality products globally to hundreds of customers in all 5 continents. New cables are designed constantly, with a focus on data-communication cables for ship and offshore applications. The cables are approved by DNV-GL/ABS and certified by 3rd party independent testing laboratories to meet all relevant international standards. All of our DNV-GL/ABS approved cables are supplied with unique cross-linked, flame-retardant low smoke zero halogen jacketing materials. Many of our DNV-GL/ABS cables meet the stringent IEC 60331 flame test for circuit integrity to be used in "Mission Critical" applications. In addition to the following DNV-GL/ABS cable groups, we also design and manufacture custom and hybrid cable constructions.


To download Teldor's Offshore Cable Solutions Brochure - click here


     
Teldor Cables & Systems
DNV & ABS Certified Off-Shore, Marine, Oil and Gas Cables
150/250V (300V) Halogen free, Low smoke Instrumentation & Control Cables
Optional Constructions
This page outlines some of the common cable types supplied by Teldor.
Alternative constructions including other conductors, shields, armors and mud-resistance are included in the DNV and ABS certificates and are available upon request.

Available options:
  • Conductor material: Bare copper or Tin-coated copper
  • Conductor stranding: IEC 60228 Class 2 or Class 5
  • Individual shield options: None, Metal foil + drain, Metal braid or Metal foil + Metal braid
  • Individual jacket options: None, Taped or Extruded
  • Overall shield options: None, Metal foil + drain, Metal braid or Metal foil + Metal braid
  • Inner jacket options: None, IEC 60092-359 & IEC 60092-360 SHF1 or SHF2
  • Braided armor options: Bare or Tinned copper, Galvanized steel, Aluminum alloy, Copper alloy or Bronze
  • Outer jacket options: IEC 60092-359 & IEC 60092-360 SHF1, IEC 60092-359 & IEC 60092-360 SHF2 with or without MUD resistance

150/250V (300V) Armored, Flame retardant, Halogen free, Low smoke Instrumentation and control cables (DF1)
DNV Certificate:E-13818 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF1
Mud resistance: No
150/250V (300V) Armored, Flame retardant, Halogen free, Low smoke Instrumentation and control MUD Resistant cables (DF2)
DNV Certificate:E-13706 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359, IEC 60092-360 & NEK 606
Flame tests: IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2
Mud resistance: Yes
150/250V (300V) Armored, Flame retardant, Halogen free, Low smoke Instrumentation and control cables (DF3)
DNV Certificate:E-13706 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2
Mud resistance: No.
150/250V (300V) Armored, Flame retardant, Halogen free, Low smoke Instrumentation and control MUD Resistant cables (DF4)
DNV Certificate: E-12946 ABS Certificate: 14-GE1177437-PDA
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359, IEC 60092-360 & NEK 606
Flame tests: IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF2

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2
Mud resistance: Yes.
150/250V (300V) Armored, Fire-Resistant, Flame-Retardant, Halogen free, Low smoke Instrumentation and control cables (DG1)
DNV Certificate:E-13819 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60331-21, IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF1
Mud resistance: No
150/250V (300V) Armored, Fire-Resistant, Flame-Retardant, Halogen free, Low smoke Instrumentation and control MUD Resistant cables (DG2)
DNV Certificate:E-13707 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359, IEC 60092-360 & NEK 606
Flame tests: IEC 60331-21, IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2
Mud resistance: Yes
150/250V (300V) Armored, Fire-Resistant, Flame-Retardant, Halogen free, Low smoke Instrumentation and control cables (DG3)
DNV Certificate:E-13707 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60331-21, IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2
Mud resistance: No.
150/250V (300V) Armored, Fire-Resistant, Flame-Retardant, Halogen free, Low smoke Instrumentation and control MUD Resistant cables (DG4)
DNV Certificate:E-12947 ABS Certificate: 14-GE1177437-PDA
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60331-21, IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF2

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2
Mud resistance: Yes.
50/250V (300V) Non-armored, Flame-Retardant, Halogen free, Low smoke Instrumentation and control cables (DP1)
DNV Certificate:E-13820 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket: None
Armor: None
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Mud resistance: No
150/250V (300V) Non-armored, Flame-Retardant, Halogen free, Low smoke Instrumentation and control MUD Resistant cables (DP2)
DNV Certificate:E-12948 ABS Certificate: 14-GE1177437-PDA
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359, IEC 60092-360 & NEK 606
Flame tests: IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket: None
Armor: None
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2

Mud resistance: Yes
150/250V (300V) Non-armored, Flame-Retardant, Halogen free, Low smoke Instrumentation and control cables (DP3)
DNV Certificate:E-12948 ABS Certificate: 14-GE1177437-PDA
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket: None
Armor: None
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2

Mud resistance: No.
150/250V (300V) Non-armored, Fire-Resistant, Flame-Retardant, Halogen free, Low smoke Instrumentation and control cables (DQ1)
DNV Certificate:E-13821 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60331-21, IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket: None
Armor: None
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Mud resistance: No
150/250V (300V) Non-armored, Fire-Resistant, Flame-Retardant, Halogen free, Low smoke Instrumentation and control MUD Resistant cables (DQ2)
DNV Certificate:E-12949 ABS Certificate: 14-GE1177437-PDA
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359, IEC 60092-360 & NEK 606
Flame tests: IEC 60331-21, IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket: None
Armor: None
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2

Mud resistance: Yes
150/250V (300V) Non-armored, Fire-Resistant, Flame-Retardant, Halogen free, Low smoke Instrumentation and control cables (DQ3)
DNV Certificate:E-12949 ABS Certificate: 14-GE1177437-PDA
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60331-21, IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket: None
Armor: None
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2

Mud resistance: No