Home English  |  Русский  |  Español  |  Deutsch  |  Français  |  Portuguese
User Name:
Password:
Why Register?
Forgotten Password?
Product Families
Computer & LAN
FiberOptics
Industrial Ethernet & BUS
Instrumentation, Control & Signal
Electronic & Audio
Telecom
Coax
Power
Military & Defense
Specialty Cables
Product Search:
Advanced Search


SITE SEARCH

Overview of Teldor's Offshore Instrumentation & Control Cables




Teldor Cables & Systems, established in 1966, designs and manufactures over 6,500 cables for a wide range of applications including both onshore and offshore installations. Teldor supplies quality products globally to hundreds of customers in all 5 continents. New cables are designed constantly, with a focus on data-communication cables for ship and offshore applications. The cables are approved by DNV-GL/ABS and certified by 3rd party independent testing laboratories to meet all relevant international standards. All of our DNV-GL/ABS approved cables are supplied with unique cross-linked, flame-retardant low smoke zero halogen jacketing materials. Many of our DNV-GL/ABS cables meet the stringent IEC 60331 flame test for circuit integrity to be used in "Mission Critical" applications. In addition to the following DNV-GL/ABS cable groups, we also design and manufacture custom and hybrid cable constructions.


To download Teldor's Offshore Cable Solutions Brochure - click here


     
Teldor Cables & Systems
DNV & ABS Certified Off-Shore, Marine, Oil and Gas Cables
150/250V (300V) Halogen free, Low smoke Instrumentation & Control Cables
Optional Constructions
This page outlines some of the common cable types supplied by Teldor.
Alternative constructions including other conductors, shields, armors and mud-resistance are included in the DNV and ABS certificates and are available upon request.

Available options:
  • Conductor material: Bare copper or Tin-coated copper
  • Conductor stranding: IEC 60228 Class 2 or Class 5
  • Individual shield options: None, Metal foil + drain, Metal braid or Metal foil + Metal braid
  • Individual jacket options: None, Taped or Extruded
  • Overall shield options: None, Metal foil + drain, Metal braid or Metal foil + Metal braid
  • Inner jacket options: None, IEC 60092-359 & IEC 60092-360 SHF1 or SHF2
  • Braided armor options: Bare or Tinned copper, Galvanized steel, Aluminum alloy, Copper alloy or Bronze
  • Outer jacket options: IEC 60092-359 & IEC 60092-360 SHF1, IEC 60092-359 & IEC 60092-360 SHF2 with or without MUD resistance

150/250V (300V) Armored, Flame retardant, Halogen free, Low smoke Instrumentation and control cables (DF1)
DNV Certificate:E-13818 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF1
Mud resistance: No
150/250V (300V) Armored, Flame retardant, Halogen free, Low smoke Instrumentation and control MUD Resistant cables (DF2)
DNV Certificate:E-13706 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359, IEC 60092-360 & NEK 606
Flame tests: IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2
Mud resistance: Yes
150/250V (300V) Armored, Flame retardant, Halogen free, Low smoke Instrumentation and control cables (DF3)
DNV Certificate:E-13706 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2
Mud resistance: No.
150/250V (300V) Armored, Flame retardant, Halogen free, Low smoke Instrumentation and control MUD Resistant cables (DF4)
DNV Certificate: E-12946 ABS Certificate: 14-GE1177437-PDA
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359, IEC 60092-360 & NEK 606
Flame tests: IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF2

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2
Mud resistance: Yes.
150/250V (300V) Armored, Fire-Resistant, Flame-Retardant, Halogen free, Low smoke Instrumentation and control cables (DG1)
DNV Certificate:E-13819 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60331-21, IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF1
Mud resistance: No
150/250V (300V) Armored, Fire-Resistant, Flame-Retardant, Halogen free, Low smoke Instrumentation and control MUD Resistant cables (DG2)
DNV Certificate:E-13707 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359, IEC 60092-360 & NEK 606
Flame tests: IEC 60331-21, IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2
Mud resistance: Yes
150/250V (300V) Armored, Fire-Resistant, Flame-Retardant, Halogen free, Low smoke Instrumentation and control cables (DG3)
DNV Certificate:E-13707 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60331-21, IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2
Mud resistance: No.
150/250V (300V) Armored, Fire-Resistant, Flame-Retardant, Halogen free, Low smoke Instrumentation and control MUD Resistant cables (DG4)
DNV Certificate:E-12947 ABS Certificate: 14-GE1177437-PDA
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60331-21, IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket material: IEC 60092-359 & IEC 60092-360 SHF2

Armor: Braided galvanized steel wires
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2
Mud resistance: Yes.
50/250V (300V) Non-armored, Flame-Retardant, Halogen free, Low smoke Instrumentation and control cables (DP1)
DNV Certificate:E-13820 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket: None
Armor: None
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Mud resistance: No
150/250V (300V) Non-armored, Flame-Retardant, Halogen free, Low smoke Instrumentation and control MUD Resistant cables (DP2)
DNV Certificate:E-12948 ABS Certificate: 14-GE1177437-PDA
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359, IEC 60092-360 & NEK 606
Flame tests: IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket: None
Armor: None
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2

Mud resistance: Yes
150/250V (300V) Non-armored, Flame-Retardant, Halogen free, Low smoke Instrumentation and control cables (DP3)
DNV Certificate:E-12948 ABS Certificate: 14-GE1177437-PDA
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket: None
Armor: None
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2

Mud resistance: No.
150/250V (300V) Non-armored, Fire-Resistant, Flame-Retardant, Halogen free, Low smoke Instrumentation and control cables (DQ1)
DNV Certificate:E-13821 ABS Certificate: Pending
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60331-21, IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket: None
Armor: None
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF1

Mud resistance: No
150/250V (300V) Non-armored, Fire-Resistant, Flame-Retardant, Halogen free, Low smoke Instrumentation and control MUD Resistant cables (DQ2)
DNV Certificate:E-12949 ABS Certificate: 14-GE1177437-PDA
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359, IEC 60092-360 & NEK 606
Flame tests: IEC 60331-21, IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket: None
Armor: None
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2

Mud resistance: Yes
150/250V (300V) Non-armored, Fire-Resistant, Flame-Retardant, Halogen free, Low smoke Instrumentation and control cables (DQ3)
DNV Certificate:E-12949 ABS Certificate: 14-GE1177437-PDA
Applicable Standards: IEC 60092-376, IEC 60092-350, IEC 60092-359 & IEC 60092-360
Flame tests: IEC 60331-21, IEC 60332-3-22, IEC 60332-3-24, IEC 60754 & IEC 61034
Details
Conductors: Tin coated copper, IEC 60228 Class 2
Multicore cables: Overall foil shield
Multipair & multitriad cables: Individual and overall foil shields with drain wires
Individual jacket on pairs or triads: None
Inner jacket: None
Armor: None
Outer jacket material: IEC 60092-359 & IEC 60092-360 SHF2

Mud resistance: No