Generic P/N Image Product Description PDF
3101580101 1.5 mm2 Flexible PVC Insulated Single Core Conductor
Applications: Electric internal wiring, Power, lighting and control, Outdoor Plant, General Construction: 1.5 mm2 PVC insulated flexible conductor, Conductor Cross Section: 1.5mm², Outer Diameter: 5.0mm nom., Weight: 38.5kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1, Dielectric Strength: 2000V/15 minutes
3307200xxx 2x0.75 mm2 Electrical Flexible Cord
Applications: Portable electrical equipment, General Construction: 2 PVC insulated 0.75 mm2 flexible wires cabled together and jacketed with PVC. This cable is officially approved by SII to the PTTH Type per IS 473.8., Conductor Cross Section: 0.75mm², Outer Jacket Material: FR-PVC, Outer Diameter: 6.6mm nom., Weight: 60kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1, Dielectric Strength: 2000V/15 minutes
3415400101 4x1.5 mm2 NYM Electrical Power Cable
Applications: Low voltage power, Power and control, Household appliances, Outdoor Plant, Underground Installations, General Construction: 4 PVC insulated 1.5 mm2 solid wires, cabled together, inner PVC covering and outer  PVC  jacket. This cable is officially approved by SII to Israeli Standard 60227 part 4., Conductor Cross Section: 1.5mm², Outer Jacket Material: PVC, Outer Diameter: 10.0mm nom., Weight: 200kg/km, Flamability Rating: IEC 60332-1, Dielectric Strength: 2000V/15 minutes
352502H101 2X2.5 mm2 HFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 2 HFFR insulated 2.5 mm2 CL2 stranded wires, cabled together and double jacketed with HFFR, per  IEC 60502 part1., Conductor Cross Section: 2.5mm², Outer Jacket Material: HFFR, Outer Diameter: 12.5mm nom., Weight: 230kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
354002H101 2X4 mm2 HFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 2 HFFR insulated 4 mm2 CL2 stranded wires, cabled together, and double jacketed with HFFR, per  IEC 60502 part1., Conductor Cross Section: 4.0mm², Outer Jacket Material: HFFR, Outer Diameter: 14.5mm nom., Weight: 320kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
354003H101 3X4 mm2 HFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 wires are cabled together and double jacketed., Conductor Cross Section: 4.0mm², Outer Jacket Material: HFFR, Outer Diameter: 15.5mm nom., Weight: 375kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
356002H101 2X6 mm2 NYY 0.6/1.0 KV Electrical Power Cable
Applications: Low voltage power, Power and control, General Construction: 2 Wires are cabled together. An inner covering and outer  jacket complete the cable structure., Conductor Cross Section: 6.0mm², Outer Jacket Material: HFFR, Outer Diameter: 14.7mm nom., Weight: 350kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
359001H101 1X10 mm2 HFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 1 HFFR insulated 10 mm2 CL2 stranded wire, with outdoor HFFR jacket   per  IEC 60502 part1., Conductor Cross Section: 10.0mm², Outer Jacket Material: HFFR, Outer Diameter: 9.7mm nom., Weight: 195kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
35H1403101 3X14 AWG 0.6/1.0 KV HFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Underground Installations, General Construction: 3 - wires are cabled together and covered with an inner covering and an outer  jacket., Outer Jacket Material: HFFR, Outer Diameter: 13.5mm nom., Weight: 250kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 3400V/10 minutes
35H1502101 2X1.5 mm2 0.6/1.0 KV HFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 2 HFFR insulated 1.5 mm2 wires are cabled together,an  inner HFFR covering and an outer  HFFR  jacket complete the cable sructure., Conductor Cross Section: 1.5mm², Outer Jacket Material: HFFR, Outer Diameter: 11.6mm nom., Weight: 185kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 3400V/10 minutes
35H1503101 3X1.5 mm2 0.6/1.0 KV HFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 HFFR insulated 1.5 mm2 wires are cabled together,an  inner HFFR  covering and an outer  HFFR  jacket complete the cable sructure., Conductor Cross Section: 1.5mm², Outer Jacket Material: HFFR, Outer Diameter: 12.0mm nom., Weight: 215kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 3400V/10 minutes
35H1504101 4X1.5 mm2 0.6/1.0 KV HFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 4 HFFR insulated 1.5 mm2 wires are cabled together,an  inner HFFR  covering and an outer  HFFR  jacket complete the cable sructure., Conductor Cross Section: 1.5mm², Outer Jacket Material: HFFR, Outer Diameter: 13.0mm nom., Weight: 255kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 3400V/10 minutes
35H1505101 5X1.5 mm2 0.6/1.0 KV HFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 5 HFFR insulated 1.5 mm2 wires are cabled together,an  inner HFFR  covering and an outer  HFFR  jacket complete the cable sructure., Conductor Cross Section: 1.5mm², Outer Jacket Material: HFFR, Outer Diameter: 14mm nom., Weight: 280kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 3400V/10 minutes
35H1507101 7X1.5 mm2 0.6/1.0 KV HFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 7 HFFR insulated 1.5 mm2 wires are cabled together,an  inner HFFR  covering and an outer  HFFR  jacket complete the cable sructure., Conductor Cross Section: 1.5mm², Outer Jacket Material: HFFR, Outer Diameter: 15mm nom., Weight: 330kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 3400V/10 minutes
35H1510101 10X1.5 mm2 0.6/1.0 KV HFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 10 HFFR insulated 1.5 mm2 wires are cabled together,an  inner HFFR  covering and an outer  HFFR  jacket complete the cable sructure., Conductor Cross Section: 1.5mm², Outer Jacket Material: HFFR, Outer Diameter: 18mm nom., Weight: 445kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 3400V/10 minutes
35H15A3101 3X1.5 mm2 HFFR 0.6/1.0 KV Underground Armored Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 HFFR insulated 1.5 mm2 CL2 wires are cabled together,an inner HFFR jacket is applied ,followed by Served Steel Wire Armor (Rodent Protection)  and an outer  HFFR  jacket., Conductor Cross Section: 1.5mm², Outer Jacket Material: HFFR, Outer Diameter: 15.0mm nom., Weight: 430kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
35H2503101 3X2.5 mm2 0.6/1.0 KV HFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 HFFR insulated 2.5 mm2 wires are cabled together,an inner HFFR  covering and  an outer  HFFR  jacket complete the cable structure., Conductor Cross Section: 2.5mm², Outer Jacket Material: HFFR, Outer Diameter: 13.0mm nom., Weight: 265kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 3400V/10 minutes
35H25A3101 3X2.5 mm2 HFFR 0.6/1.0 KV Underground Armored Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 HFFR insulated 2.5 mm2 CL2 wires are cabled together,an inner HFFR jacket is applied , followed by Served Steel Wire Armor (Rodent Protection)  and an outer  HFFR  jacket ., Conductor Cross Section: 2.5mm², Outer Jacket Material: HFFR, Outer Diameter: 16.0mm nom., Weight: 500kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
35H4003101 3X4 mm2 0.6/1.0 KV HFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 HFFR insulated 4 mm2 wires are cabled together, an inner  HFFR  covering and an outer  HFFR  jacket complete the cable structure., Conductor Cross Section: 4.0mm², Outer Jacket Material: HFFR, Outer Diameter: 15.5mm nom., Weight: 360kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 3400V/10 minutes
35H4U03101 3X4 mm2 0.6/1.0 KV HFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 wires are cabled together. An inner covering and an outer jacket complete the cable structure., Conductor Cross Section: 4.0mm², Outer Jacket Material: XL-HFFR, Outer Diameter: 14.5mm nom., Weight: 335kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 3400V/10 minutes
35H4UA3101 3X4 mm2 0.6/1.0 KV HFFR Underground Armored Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 wires are cabled together. An inner covering followed by a Steel Wire Armor (Rodent Protection) and an outer  jacket complete the cable structure., Conductor Cross Section: 4.0mm², Outer Jacket Material: XL-HFFR, Outer Diameter: 17.0mm nom., Weight: 585kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 3400V/10 minutes
35H4UB3101 3X14 AWG 0.6/1.0 KV XLHFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, Outdoor Plant, Underground Installations, General Construction: 3 wires are cabled together. An inner covering and an outer jacket complete the cable structure., Outer Jacket Material: XL-HFFR, Outer Diameter: 13.5mm nom., Weight: 242kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 2000V/15 minutes
35H4UC3101 3X8 AWG 0.6/1.0 KV XLHFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, Outdoor Plant, Underground Installations, General Construction: 3 wires are cabled together. An inner covering and an outer jacket complete the cable structure., Outer Jacket Material: XL-HFFR, Outer Diameter: 18.5mm nom., Weight: 550kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 2000V/15 minutes
35H4UD3101 3X6 AWG 0.6/1.0 KV XLHFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, Outdoor Plant, Underground Installations, General Construction: 3 wires are cabled together. An inner covering and an outer jacket complete the cable structure., Outer Jacket Material: XL-HFFR, Outer Diameter: 20.5mm nom., Weight: 710kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 2000V/15 minutes
3611004101 4x1.0 mm2 CL5 NYCY Shielded Electric Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 4 wires are cabled together and jacketed. A metallic screen of copper wires and copper tape followed by an outer jacket complete the cables structure., Conductor Cross Section: 1.0mm², Outer Jacket Material: PVC, Outer Diameter: 13.6mm nom., Weight: 255kg/km, Dielectric Strength: 2400V/15 minutes
3611007101 7x1.0 mm2 CL5 NYCY Shielded Electric Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 7 wires are cabled together and jacketed. A metallic screen of copper wires and copper tape followed by an outer jacket complete the cables structure., Conductor Cross Section: 1.0mm², Outer Jacket Material: PVC, Outer Diameter: 15.5mm nom., Weight: 315kg/km, Dielectric Strength: 2400V/15 minutes
3611018101 18x1.0 mm2 CL5 NYCY Shielded Electric Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 18 wires are cabled together and jacketed. A metallic screen of copper wires and copper tape followed by an outer jacket complete the cables structure., Conductor Cross Section: 1.0mm², Outer Jacket Material: PVC, Outer Diameter: 20.0mm nom., Weight: 600kg/km, Dielectric Strength: 2400V/15 minutes
3611024101 24x1.0 mm2 CL5 NYCY Shielded Electric Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 24 wires are cabled together and jacketed. A metallic screen of copper wires and copper tape followed by an outer jacket complete the cables structure., Conductor Cross Section: 1.0mm², Outer Jacket Material: PVC, Outer Diameter: 23.5mm nom., Weight: 735kg/km, Dielectric Strength: 2400V/15 minutes
3612514101 14x2.5 mm2 CL5 NYCY Shielded Electric Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 14 wires are cabled together and jacketed. A metallic screen of copper wires and copper tape followed by an outer jacket complete the cables structure., Conductor Cross Section: 2.5mm², Outer Jacket Material: PVC, Outer Diameter: 23.1mm nom., Weight: 830kg/km, Dielectric Strength: 2400V/15 minutes
3612524101 24x2.5 mm2 CL5 NYCY Shielded Electric Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 24 wires are cabled together and jacketed. A metallic screen of copper wires and copper tape followed by an outer jacket complete the cables structure., Conductor Cross Section: 2.5mm², Outer Jacket Material: PVC, Outer Diameter: 29.5mm nom., Weight: 1325kg/km, Dielectric Strength: 2400V/15 minutes

1 2 3 >>>>>|