Home
English
|
Русский
|
Español
|
Deutsch
Cables & Systems Ltd.
ABOUT US
Company Profile
Environment
Technologies
Development
General Warranty
Terms and Conditions of Sale
Business Partners
Our Distributors in North America
Our Distributors in Africa
NEWS
Headlines
Press Releases
Events
Announcements
PRODUCT BROCHURES
The BASIC Solution
TM
The GIGA Solution
TM
The GIGA-STAR Solution
TM
The TERA-DOR Solution
TM
The CONTROL Solution
TM
RUS Copper OSP Cables
The Hook-Up Solution
Previous Synergy Products
LD Cable Family
ADSS Cable Family
MU Cable Family
SL Cable Family
MT Cable Family
MC Cable Family
Fiber Specifications
FiberOptic Color Code
QUALITY
QA Program
Teldor's Product Warranty
Certifications
SUPPORT
Designers' Forum
White Papers
Web Site Support
Help with PDF Files
Quotes and RFI
SITE
Site Map
Site Search
Contact Us
CONTACT US
Teldor Departments
Links
Marketing and Sales
User Name:
Password:
Why Register?
Forgotten Password?
Product Families
Computer & LAN
Cat. 3
Cat. 5
Cat. 5e
Cat. 6
Cat. 6
A
Cat. 7
Cat. 7
A
1200 MHz
xDSL
120 Ω E1/T1
IBM-Type 150 Ω
Specialty
FiberOptics
Indoor
Indoor/Outdoor
Outdoor
Tactical
Specialty
Industrial Ethernet & BUS
Industrial Ethernet
CanBUS
ProfiBUS
DeviceNET
InterBUS
FieldBUS-H1
FieldBUS-H2
RS-485/422
RS-232
Specialty
Low Capacitance 2x24/1 AWG F/UTP FR-LSZH
Instrumentation, Control & Signal
300V
300V Shielded
300V Shield+Armor
300V Shield+MB
600V
600V Shielded
600V Shield+Armor
600V Shield+MB
Thermocouples
Fire Alarm & Control
Solid Conductor Control
Specialty
Electronic & Audio
Microphone
Analog A/V
Digital A/V
Electronics
Hook-up
Specialty
Telecom
Switchboard
Outdoor Trunk
Access Trunk
Figure-8
Drop
Specialty
Coax
MIL C-17
MIL TYPES
75 Ω
50 Ω
Specialty
Power
Single Wires
Flexible Cords
0.6/1.0 KV PVC Underground Cables
0.6/1.0 KV XLPE Underground Cables
Heating Wires
Speaker Cables
Specialty
Military & Defense
Ground Forces
Tactical/Rapid Deployment
Shipboard
Hook-Up
Mil/Aero
Specialty
Specialty Cables
Specialty
Hybrid Cables
Product Search:
Advanced Search
SITE SEARCH
Power /
0.6/1.0 KV XLPE Underground Cables
Filter Search Results By:
Standards:
Select
IS 547
SI 60227
IEC 60502 (IS 1516)
Control
Specialty
IS 473
Design:
Select
LIYY
LIYCY
LIYYCY
NYY
NYCY
N2XY
N2XCY
473/1
473/2
Specialty
Conductor Size:
Select
0.25 mm
2
0.4 mm
2
0.5 mm
2
0.75 mm
2
1.00 mm
2
1.50 mm
2
2.50 mm
2
4.00 mm
2
6.00 mm
2
10.00 mm
2
Generic P/N
Image
Product Description
PDF
35H4UB3101
3X14 AWG 0.6/1.0 KV XLHFFR Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, 90°C applications, Outdoor Plant, Underground Installations,
General Construction:
3 wires are cabled together. An inner covering and an outer jacket complete the cable structure.,
Outer Jacket Material:
XL-HFFR,
Outer Diameter:
13.5mm nom.,
Weight:
242kg/km,
Flamability Rating:
IEC 60332-3,
Dielectric Strength:
2000V/15 minutes
35H4UC3101
3X8 AWG 0.6/1.0 KV XLHFFR Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, 90°C applications, Outdoor Plant, Underground Installations,
General Construction:
3 wires are cabled together. An inner covering and an outer jacket complete the cable structure.,
Outer Jacket Material:
XL-HFFR,
Outer Diameter:
18.5mm nom.,
Weight:
550kg/km,
Flamability Rating:
IEC 60332-3,
Dielectric Strength:
2000V/15 minutes
35H4UD3101
3X6 AWG 0.6/1.0 KV XLHFFR Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, 90°C applications, Outdoor Plant, Underground Installations,
General Construction:
3 wires are cabled together. An inner covering and an outer jacket complete the cable structure.,
Outer Jacket Material:
XL-HFFR,
Outer Diameter:
20.5mm nom.,
Weight:
710kg/km,
Flamability Rating:
IEC 60332-3,
Dielectric Strength:
2000V/15 minutes
35R1503101
3x1.5 mm
2
Armored Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
3 insulated stranded wires( class 2 per IEC 60228) are cabled together and jacketed. A steel wire armor and an outer jacket complete the cable structure.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
14.7mm nom.,
Weight:
390kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
35R2503101
3x2.5 mm
2
Armored Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
3 insulated stranded wires( class 2 per IEC 60228) are cabled together and jacketed. A steel wire armor and an outer jacket complete the cable structure.,
Conductor Cross Section:
2.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
15.5mm nom.,
Weight:
450kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
35R2504101
4x2.5 mm
2
Armored Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
4 insulated stranded wires( class 2 per IEC 60228) are cabled together and jacketed. A steel wire armor and an outer jacket complete the cable structure.,
Conductor Cross Section:
2.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
16.5mm nom.,
Weight:
505kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
35R2505101
5x2.5 mm
2
Armored Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
5 insulated stranded wires( class 2 per IEC 60228) are cabled together and jacketed. A steel wire armor and an outer jacket complete the cable structure.,
Conductor Cross Section:
2.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
17.5mm nom.,
Weight:
575kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
35T1503101
3x1.5 mm
2
Armored Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
3 insulated stranded wires( class 2 per IEC 60228) are cabled together and jacketed. A steel wire armor and an outer jacket complete the cable structure.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
14.7mm nom.,
Weight:
390kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
35T1512101
12x1.5 mm
2
Armored Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
12 insulated stranded wires( class 2 per IEC 60228) are cabled together and jacketed. A steel wire armor and an outer jacket complete the cable structure.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
21.5mm nom.,
Weight:
880kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
35T1518101
18x1.5 mm
2
Armored Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
18 insulated stranded wires( class 2 per IEC 60228) are cabled together and jacketed. A steel wire armor and an outer jacket complete the cable structure.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
24.5mm nom.,
Weight:
1115kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
35X1003101
3x10 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
3 CL5 Insulated stranded wires are cabled together and covered with an inner bedding. An outer heavy duty jacket completes the cable structure.,
Outer Jacket Material:
XL-HFFR,
Outer Diameter:
16.0mm nom.,
Weight:
405kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
2000V/15 minutes
35X1005101
5x10 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
5 CL5 Insulated stranded wires are cabled together and covered with an inner bedding. An outer heavy duty jacket completes the cable structure.,
Outer Jacket Material:
XL-HFFR,
Outer Diameter:
19.0mm nom.,
Weight:
580kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
2000V/15 minutes
35X1201101
1x12 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
1 CL5 Insulated stranded wire is jacketed.,
Outer Jacket Material:
XL-HFFR,
Outer Diameter:
7.6mm nom.,
Weight:
93kg/km,
Flamability Rating:
IEC 60332-1, IEEE 383,
Dielectric Strength:
2000V/15 minutes
35X1203101
3x12 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
3 CL5 Insulated stranded wires are cabled together and covered with an inner bedding. An outer heavy duty jacket completes the cable structure.,
Outer Jacket Material:
XL-HFFR,
Outer Diameter:
14.5mm nom.,
Weight:
310kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
2000V/15 minutes
35X1205101
5x12 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
5 CL5 Insulated stranded wires are cabled together and covered with an inner bedding. An outer heavy duty jacket completes the cable structure.,
Outer Jacket Material:
XL-HFFR,
Outer Diameter:
16.5mm nom.,
Weight:
430kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
2000V/15 minutes
35X1401101
1x14 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
1 CL5 Insulated stranded wire is jacketed.,
Outer Jacket Material:
XL-HFFR,
Outer Diameter:
7.1mm nom.,
Weight:
75kg/km,
Flamability Rating:
IEC 60332-1, IEEE 383,
Dielectric Strength:
2000V/15 minutes
35X1601101
1x16 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
1 CL5 Insulated stranded wire is jacketed.,
Outer Jacket Material:
XL-HFFR,
Outer Diameter:
6.8mm nom.,
Weight:
63kg/km,
Flamability Rating:
IEC 60332-1, IEEE 383,
Dielectric Strength:
2000V/15 minutes
35X1801101
1x18 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
1 CL5 Insulated stranded wire is jacketed.,
Outer Jacket Material:
XL-HFFR,
Outer Diameter:
6.5mm nom.,
Weight:
57kg/km,
Flamability Rating:
IEC 60332-1, IEEE 383,
Dielectric Strength:
2000V/15 minutes
35X1803101
3x18 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
3 CL5 Insulated stranded wires are cabled together and covered with an inner bedding. An outer heavy duty jacket completes the cable structure.,
Outer Jacket Material:
XL-HFFR,
Outer Diameter:
12.0mm nom.,
Weight:
190kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
2000V/15 minutes
3722501106
1X2.5 mm
2
N2XY Flexible Electrical Power Cable
Applications:
Low voltage power, Power and control, 90°C applications,
General Construction:
1 XLPE insulated 2.5 mm
2
flexible wire (class 5 per IEC 60228), with an outer PVC jacket.,
Conductor Cross Section:
2.5mm²,
Outer Jacket Material:
FR-PVC -50°C to +105°C rating,
Outer Diameter:
7.2mm nom.,
Weight:
73kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3722503106
3X2.5 mm
2
N2XY Flexible Electrical Power Cable
Applications:
Low voltage power, Power and control, 90°C applications,
General Construction:
3 XLPE insulated 2.5 mm
2
flexible wires (class 5 per IEC 60228), cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 1516/1.,
Conductor Cross Section:
2.5mm²,
Outer Jacket Material:
FR-PVC -50°C to +105°C rating,
Outer Diameter:
13.5mm nom.,
Weight:
245kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3722507106
7X2.5 mm
2
N2XY Flexible Electrical Power Cable
Applications:
Low voltage power, Power and control, 90°C applications,
General Construction:
7 XLPE insulated 2.5 mm
2
flexible wires (class 5 per IEC 60228), cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 1516/1.,
Conductor Cross Section:
2.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
16.5mm nom.,
Weight:
400kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3722512106
12X2.5 mm
2
N2XY Flexible Electrical Power Cable
Applications:
Low voltage power, Power and control, 90°C applications,
General Construction:
12 XLPE insulated 2.5 mm
2
flexible wires (class 5 per IEC 60228), cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 1516/1.,
Conductor Cross Section:
2.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
21.0mm nom.,
Weight:
600kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3722524106
24X2.5 mm
2
N2XY Flexible Electrical Power Cable
Applications:
Low voltage power, Power and control, 90°C applications, Outdoor Plant, Underground Installations,
General Construction:
24 XLPE insulated 2.5 mm
2
flexible wires (class 5 per IEC 60228), cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 1516/1.,
Conductor Cross Section:
2.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
28.5mm nom.,
Weight:
1130kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
37225A3101
3x2.5 mm
2
N2XH Armored Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
3 Insulated flexible wires (class 5 per IEC 60228) are cabled together, inner bedded and jacketed. A corrugated steel tape armor bonded to an outer jacket complete the cable structure.,
Conductor Cross Section:
2.5mm²,
Outer Jacket Material:
FR-PE,
Outer Diameter:
18.0mm nom.,
Weight:
430kg/km,
Dielectric Strength:
3400V/10 minutes
37225G3106
3x2.5 mm
2
N2XH Flexible Electrical Power Cable
Applications:
Low voltage power, Power and control, 90°C applications, Fixed Indoor installation,
General Construction:
3 Insulated flexible wires (class 5 per IEC 60228) are cabled together. An inner covering and outer jacket complete the cable structure. This is a Shipboard Power Cable.,
Conductor Cross Section:
2.5mm²,
Outer Jacket Material:
HFFR,
Outer Diameter:
13.5mm nom.,
Weight:
265kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3726003106
3X6 mm
2
N2XY Flexible Electrical Power Cable
Applications:
Low voltage power, Power and control, 90°C applications,
General Construction:
3 XLPE insulated 6 mm
2
flexible wires (class 5 per IEC 60228), cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 1516/1.,
Conductor Cross Section:
6.0mm²,
Outer Jacket Material:
FR-PVC -50°C to +105°C rating,
Outer Diameter:
16.0mm nom.,
Weight:
405kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
37260G3106
3X6 mm
2
N2XH Flexible Electrical Power Cable
Applications:
Low voltage power, Power and control, 90°C applications, Fixed Indoor installation,
General Construction:
3 Insulated flexible wires (class 5 per IEC 60228) are cabled together. An inner covering and outer jacket complete the cable structure. This is a Shipboard Power Cable.,
Conductor Cross Section:
6.0mm²,
Outer Jacket Material:
HFFR,
Outer Diameter:
16.0mm nom.,
Weight:
420kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
37260S4106
4x6 mm
2
N2XH Flexible Electrical Power Cable
Applications:
Low voltage power, Power and control, 90°C applications, Fixed Indoor installation,
General Construction:
4 Insulated flexible wires (class 5 per IEC 60228) are cabled together. An inner covering and outer jacket complete the cable structure. This is a Shipboard Power Cable.,
Conductor Cross Section:
6.0mm²,
Outer Jacket Material:
HFFR,
Outer Diameter:
17.5mm nom.,
Weight:
500kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3726C04106
4X6.0 mm
2
XLPE Shielded Electrical Power Cable
Applications:
Low voltage power, Power and control, 90°C applications,
General Construction:
4 - XLPE insulated 6.0 mm
2
wires are cabled together and overall foil shielded, an inner PVC covering and an outer PVC jacket complets the cable structure.,
Conductor Cross Section:
6.0mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
17.5mm nom.,
Weight:
505kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
1
2
3
4
5
6
>>>
>>|
Send selected products by email
Hide
Specify email:
Comment:
Terms of Use
|
Privacy Policy
|
Web Development
TELDOR Cables & Systems Ltd. - Ein-Dor, 19335 ISRAEL Tel: +972-4-6770555 Fax: +972-4-6770650