Power  /  0.6/1.0 KV XLPE Underground Cables

Filter Search Results By:

Standards:
Design:
Conductor Size:
 


Generic P/N Image Product Description PDF
35H4UB3101 3X14 AWG 0.6/1.0 KV XLHFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, Outdoor Plant, Underground Installations, General Construction: 3 wires are cabled together. An inner covering and an outer jacket complete the cable structure., Outer Jacket Material: XL-HFFR, Outer Diameter: 13.5mm nom., Weight: 242kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 2000V/15 minutes
35H4UC3101 3X8 AWG 0.6/1.0 KV XLHFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, Outdoor Plant, Underground Installations, General Construction: 3 wires are cabled together. An inner covering and an outer jacket complete the cable structure., Outer Jacket Material: XL-HFFR, Outer Diameter: 18.5mm nom., Weight: 550kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 2000V/15 minutes
35H4UD3101 3X6 AWG 0.6/1.0 KV XLHFFR Underground Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, Outdoor Plant, Underground Installations, General Construction: 3 wires are cabled together. An inner covering and an outer jacket complete the cable structure., Outer Jacket Material: XL-HFFR, Outer Diameter: 20.5mm nom., Weight: 710kg/km, Flamability Rating: IEC 60332-3, Dielectric Strength: 2000V/15 minutes
35R1503101 3x1.5 mm2 Armored Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 insulated stranded wires( class 2 per IEC 60228) are cabled together and jacketed. A steel wire armor and an outer jacket complete the cable structure., Conductor Cross Section: 1.5mm², Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 14.7mm nom., Weight: 390kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
35R2503101 3x2.5 mm2 Armored Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 insulated stranded wires( class 2 per IEC 60228) are cabled together and jacketed. A steel wire armor and an outer jacket complete the cable structure., Conductor Cross Section: 2.5mm², Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 15.5mm nom., Weight: 450kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
35R2504101 4x2.5 mm2 Armored Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 4 insulated stranded wires( class 2 per IEC 60228) are cabled together and jacketed. A steel wire armor and an outer jacket complete the cable structure., Conductor Cross Section: 2.5mm², Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 16.5mm nom., Weight: 505kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
35R2505101 5x2.5 mm2 Armored Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 5 insulated stranded wires( class 2 per IEC 60228) are cabled together and jacketed. A steel wire armor and an outer jacket complete the cable structure., Conductor Cross Section: 2.5mm², Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 17.5mm nom., Weight: 575kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
35T1503101 3x1.5 mm2 Armored Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 insulated stranded wires( class 2 per IEC 60228) are cabled together and jacketed. A steel wire armor and an outer jacket complete the cable structure., Conductor Cross Section: 1.5mm², Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 14.7mm nom., Weight: 390kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
35T1512101 12x1.5 mm2 Armored Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 12 insulated stranded wires( class 2 per IEC 60228) are cabled together and jacketed. A steel wire armor and an outer jacket complete the cable structure., Conductor Cross Section: 1.5mm², Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 21.5mm nom., Weight: 880kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
35T1518101 18x1.5 mm2 Armored Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 18 insulated stranded wires( class 2 per IEC 60228) are cabled together and jacketed. A steel wire armor and an outer jacket complete the cable structure., Conductor Cross Section: 1.5mm², Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 24.5mm nom., Weight: 1115kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
35X1003101 3x10 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 CL5 Insulated stranded wires are cabled together and covered with an inner bedding. An outer heavy duty jacket completes the cable structure., Outer Jacket Material: XL-HFFR, Outer Diameter: 16.0mm nom., Weight: 405kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 2000V/15 minutes
35X1005101 5x10 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 5 CL5 Insulated stranded wires are cabled together and covered with an inner bedding. An outer heavy duty jacket completes the cable structure., Outer Jacket Material: XL-HFFR, Outer Diameter: 19.0mm nom., Weight: 580kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 2000V/15 minutes
35X1201101 1x12 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 1 CL5 Insulated stranded wire is jacketed., Outer Jacket Material: XL-HFFR, Outer Diameter: 7.6mm nom., Weight: 93kg/km, Flamability Rating: IEC 60332-1, IEEE 383, Dielectric Strength: 2000V/15 minutes
35X1203101 3x12 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 CL5 Insulated stranded wires are cabled together and covered with an inner bedding. An outer heavy duty jacket completes the cable structure., Outer Jacket Material: XL-HFFR, Outer Diameter: 14.5mm nom., Weight: 310kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 2000V/15 minutes
35X1205101 5x12 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 5 CL5 Insulated stranded wires are cabled together and covered with an inner bedding. An outer heavy duty jacket completes the cable structure., Outer Jacket Material: XL-HFFR, Outer Diameter: 16.5mm nom., Weight: 430kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 2000V/15 minutes
35X1401101 1x14 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 1 CL5 Insulated stranded wire is jacketed., Outer Jacket Material: XL-HFFR, Outer Diameter: 7.1mm nom., Weight: 75kg/km, Flamability Rating: IEC 60332-1, IEEE 383, Dielectric Strength: 2000V/15 minutes
35X1601101 1x16 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 1 CL5 Insulated stranded wire is jacketed., Outer Jacket Material: XL-HFFR, Outer Diameter: 6.8mm nom., Weight: 63kg/km, Flamability Rating: IEC 60332-1, IEEE 383, Dielectric Strength: 2000V/15 minutes
35X1801101 1x18 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 1 CL5 Insulated stranded wire is jacketed., Outer Jacket Material: XL-HFFR, Outer Diameter: 6.5mm nom., Weight: 57kg/km, Flamability Rating: IEC 60332-1, IEEE 383, Dielectric Strength: 2000V/15 minutes
35X1803101 3x18 AWG XLHFFR 0.6/1.0 KV Underground Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 CL5 Insulated stranded wires are cabled together and covered with an inner bedding. An outer heavy duty jacket completes the cable structure., Outer Jacket Material: XL-HFFR, Outer Diameter: 12.0mm nom., Weight: 190kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 2000V/15 minutes
3722501106 1X2.5 mm2 N2XY Flexible Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, General Construction: 1 XLPE insulated 2.5 mm2 flexible wire (class 5 per IEC 60228), with an outer PVC jacket., Conductor Cross Section: 2.5mm², Outer Jacket Material: FR-PVC -50°C to +105°C rating, Outer Diameter: 7.2mm nom., Weight: 73kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
3722503106 3X2.5 mm2 N2XY Flexible Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, General Construction: 3 XLPE insulated 2.5 mm2 flexible wires (class 5 per IEC 60228), cabled together, inner PVC covering and outer  PVC  jacket. This cable is officially approved by SII to Israeli Standard 1516/1., Conductor Cross Section: 2.5mm², Outer Jacket Material: FR-PVC -50°C to +105°C rating, Outer Diameter: 13.5mm nom., Weight: 245kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
3722507106 7X2.5 mm2 N2XY Flexible Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, General Construction: 7 XLPE insulated 2.5 mm2 flexible wires (class 5 per IEC 60228), cabled together, inner PVC covering and outer  PVC  jacket. This cable is officially approved by SII to Israeli Standard 1516/1., Conductor Cross Section: 2.5mm², Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 16.5mm nom., Weight: 400kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
3722512106 12X2.5 mm2 N2XY Flexible Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, General Construction: 12 XLPE insulated 2.5 mm2 flexible wires (class 5 per IEC 60228), cabled together, inner PVC covering and outer  PVC  jacket. This cable is officially approved by SII to Israeli Standard 1516/1., Conductor Cross Section: 2.5mm², Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 21.0mm nom., Weight: 600kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
3722524106 24X2.5 mm2 N2XY Flexible Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, Outdoor Plant, Underground Installations, General Construction: 24 XLPE insulated 2.5 mm2 flexible wires (class 5 per IEC 60228), cabled together, inner PVC covering and outer  PVC  jacket. This cable is officially approved by SII to Israeli Standard 1516/1., Conductor Cross Section: 2.5mm², Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 28.5mm nom., Weight: 1130kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
37225A3101 3x2.5 mm2 N2XH Armored Electrical Power Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 Insulated flexible wires (class 5 per IEC 60228) are cabled together, inner bedded and jacketed. A corrugated steel tape armor bonded to an outer jacket complete the cable structure., Conductor Cross Section: 2.5mm², Outer Jacket Material: FR-PE, Outer Diameter: 18.0mm nom., Weight: 430kg/km, Dielectric Strength: 3400V/10 minutes
37225G3106 3x2.5 mm2 N2XH Flexible Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, Fixed Indoor installation, General Construction: 3 Insulated flexible wires (class 5 per IEC 60228) are cabled together. An inner covering and outer jacket complete the cable structure. This is a Shipboard Power Cable., Conductor Cross Section: 2.5mm², Outer Jacket Material: HFFR, Outer Diameter: 13.5mm nom., Weight: 265kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
3726003106 3X6 mm2 N2XY Flexible Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, General Construction: 3 XLPE insulated 6 mm2 flexible wires (class 5 per IEC 60228), cabled together, inner PVC covering and outer  PVC  jacket. This cable is officially approved by SII to Israeli Standard 1516/1., Conductor Cross Section: 6.0mm², Outer Jacket Material: FR-PVC -50°C to +105°C rating, Outer Diameter: 16.0mm nom., Weight: 405kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
37260G3106 3X6 mm2 N2XH Flexible Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, Fixed Indoor installation, General Construction: 3 Insulated flexible wires (class 5 per IEC 60228) are cabled together. An inner covering and outer jacket complete the cable structure. This is a Shipboard Power Cable., Conductor Cross Section: 6.0mm², Outer Jacket Material: HFFR, Outer Diameter: 16.0mm nom., Weight: 420kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
37260S4106 4x6 mm2 N2XH Flexible Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, Fixed Indoor installation, General Construction: 4 Insulated flexible wires (class 5 per IEC 60228) are cabled together. An inner covering and outer jacket complete the cable structure. This is a Shipboard Power Cable., Conductor Cross Section: 6.0mm², Outer Jacket Material: HFFR, Outer Diameter: 17.5mm nom., Weight: 500kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
3726C04106 4X6.0 mm2 XLPE Shielded Electrical Power Cable
Applications: Low voltage power, Power and control, 90°C applications, General Construction: 4 -  XLPE insulated 6.0 mm2 wires are cabled together and overall foil shielded, an inner PVC covering and an outer  PVC  jacket complets the cable structure., Conductor Cross Section: 6.0mm², Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 17.5mm nom., Weight: 505kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes

1 2 3 4 5 6 >>>>>|

Send to email Send selected products by email