Home
English
|
Русский
|
Español
|
Deutsch
Cables & Systems Ltd.
ABOUT US
Company Profile
Environment
Technologies
Development
General Warranty
Terms and Conditions of Sale
Business Partners
Our Distributors in North America
Our Distributors in Africa
NEWS
Headlines
Press Releases
Events
Announcements
PRODUCT BROCHURES
The BASIC Solution
TM
The GIGA Solution
TM
The GIGA-STAR Solution
TM
The TERA-DOR Solution
TM
The CONTROL Solution
TM
RUS Copper OSP Cables
The Hook-Up Solution
Previous Synergy Products
LD Cable Family
ADSS Cable Family
MU Cable Family
SL Cable Family
MT Cable Family
MC Cable Family
Fiber Specifications
FiberOptic Color Code
QUALITY
QA Program
Teldor's Product Warranty
Certifications
SUPPORT
Designers' Forum
White Papers
Web Site Support
Help with PDF Files
Quotes and RFI
SITE
Site Map
Site Search
Contact Us
CONTACT US
Teldor Departments
Links
Marketing and Sales
User Name:
Password:
Why Register?
Forgotten Password?
Product Families
Computer & LAN
Cat. 3
Cat. 5
Cat. 5e
Cat. 6
Cat. 6
A
Cat. 7
Cat. 7
A
1200 MHz
xDSL
120 Ω E1/T1
IBM-Type 150 Ω
Specialty
FiberOptics
Indoor
Indoor/Outdoor
Outdoor
Tactical
Specialty
Industrial Ethernet & BUS
Industrial Ethernet
CanBUS
ProfiBUS
DeviceNET
InterBUS
FieldBUS-H1
FieldBUS-H2
RS-485/422
RS-232
Specialty
Low Capacitance 2x24/1 AWG F/UTP FR-LSZH
Instrumentation, Control & Signal
300V
300V Shielded
300V Shield+Armor
300V Shield+MB
600V
600V Shielded
600V Shield+Armor
600V Shield+MB
Thermocouples
Fire Alarm & Control
Solid Conductor Control
Specialty
Electronic & Audio
Microphone
Analog A/V
Digital A/V
Electronics
Hook-up
Specialty
Telecom
Switchboard
Outdoor Trunk
Access Trunk
Figure-8
Drop
Specialty
Coax
MIL C-17
MIL TYPES
75 Ω
50 Ω
Specialty
Power
Single Wires
Flexible Cords
0.6/1.0 KV PVC Underground Cables
0.6/1.0 KV XLPE Underground Cables
Heating Wires
Speaker Cables
Specialty
Military & Defense
Ground Forces
Tactical/Rapid Deployment
Shipboard
Hook-Up
Mil/Aero
Specialty
Specialty Cables
Specialty
Hybrid Cables
Product Search:
Advanced Search
SITE SEARCH
Power /
0.6/1.0 KV PVC Underground Cables
Filter Search Results By:
Standards:
Select
IS 547
SI 60227
Control
Specialty
IS 473
Design:
Select
LIYY
LIYCY
LIYYCY
NYY
NYCY
N2XY
N2XCY
473/1
473/2
Specialty
Conductor Size:
Select
0.25 mm
2
0.4 mm
2
0.5 mm
2
0.75 mm
2
1.00 mm
2
1.50 mm
2
2.50 mm
2
4.00 mm
2
6.00 mm
2
10.00 mm
2
Generic P/N
Image
Product Description
PDF
3560A02101
2X6 mm
2
0.6/1.0 KV Shielded Electrical Power Cable
Applications:
Low voltage power, Power and control,
General Construction:
2 PVC insulated 6 mm
2
wires are cabled together with a drain wire, aluminum foil shielded, inner PVC covering and outer PVC jacket.,
Conductor Cross Section:
6.0mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
15.2mm nom.,
Weight:
350kg/km,
Flamability Rating:
IEC 60332-1,
Dielectric Strength:
3400V/10 minutes
3508B03101
3x8 AWG 0.6/1.0 KV Underground Armored Cable
Applications:
Low voltage power, Power and control, 90°C applications, Outdoor Plant, Underground Installations,
General Construction:
3 Insulated CL2 wires are cabled together and jacketed. A Served Steel Wire Armor and outer jacket complete the cable structure.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
21.5mm nom.,
Weight:
955kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515020101
2X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
2 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
10.5mm nom.,
Weight:
150kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515030101
3X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
3 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
11.1mm nom.,
Weight:
165kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1,
Dielectric Strength:
3400V/10 minutes
351503H101
3X1.5 mm
2
0.6/1.0 KV Underground Electrical Power Cable with HFFR Jacket
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
3 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer HFFR jacket.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PO,
Outer Diameter:
11.0mm nom.,
Weight:
175kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1,
Dielectric Strength:
3400V/10 minutes
3515040101
4X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
4 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
12.0mm nom.,
Weight:
200kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515050101
5X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
5 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
12.5mm nom.,
Weight:
225kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515062101
6X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Control Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
6 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
13.5mm nom.,
Weight:
225kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515072101
7X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
7 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
13.5mm nom.,
Weight:
285kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515102101
10X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
10 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
16.0mm nom.,
Weight:
370kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515122101
12X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
12 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
16.2mm nom.,
Weight:
405kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515142101
14X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
14 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
17.0mm nom.,
Weight:
460kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515162101
16X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
16 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
18.0mm nom.,
Weight:
510kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515192101
19X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
19 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
18.5mm nom.,
Weight:
605kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515212101
21X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
21 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
19.5mm nom.,
Weight:
635kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515242101
24X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
24 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
22.0mm nom.,
Weight:
750kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515372101
37X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
37 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
23.0mm nom.,
Weight:
920kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515402101
40X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
40 PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
26.0mm nom.,
Weight:
1135kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515422101
42X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
42PVC insulated 1.5 mm
2
solid wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
24.5mm nom.,
Weight:
1035kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515502101
2X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Control Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
2 PVC insulated 1.5 mm
2
CL2 wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
11.0mm nom.,
Weight:
160kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515503101
3X1.5 mm
2
NYY 0.6/1.0 KV Underground Electrical Power Control Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
3 PVC insulated 1.5 mm
2
CL2 wires, cabled together, inner PVC covering and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
11.5mm nom.,
Weight:
180kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515702101
2X1.5 mm
2
0.6/1.0 KV Shielded Electrical Control Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
2 Flexible wires (class 5) are cabled together, an inner covering is followed by a copper braid shield and outer jacketed.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
12.0mm nom.,
Weight:
200kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515703101
3X1.5 mm
2
0.6/1.0 KV Shielded Electrical Control Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
3 Flexible wires (class 5) are cabled together, an inner covering is followed by a copper braid shield and outer jacketed.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
12.5mm nom.,
Weight:
225kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515706101
6X1.5 mm
2
0.6/1.0 KV Shielded Electrical Control Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
6 Flexible wires (class 5) are cabled together, an inner covering is followed by a copper braid shield and outer jacketed.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
15.0mm nom.,
Weight:
335kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515712101
12X1.5 mm
2
0.6/1.0 KV Shielded Electrical Control Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
12 Flexible wires (class 5) are cabled together, an inner covering is followed by a copper braid shield and outer jacketed.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
19.0mm nom.,
Weight:
530kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
35157B2101
2x2x1.5 mm
2
0.6/1.0 KV Individual & Overall Shielded Electrical Control Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
2 Individually shielded twisted pairs are cabled together, an inner covering is followed by a copper braid shield and an outer jacket.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
18.0mm nom.,
Weight:
430kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515A04101
4X1.5 mm
2
0.6/1.0 KV Shielded Electrical Power Cable
Applications:
Low voltage power, Power and control,
General Construction:
4 PVC insulated 1.5 mm
2
wires are cabled together with a drain wire, aluminum foil shielded, inner PVC covering and outer PVC jacket.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
12.5mm nom.,
Weight:
220kg/km,
Flamability Rating:
IEC 60332-1,
Dielectric Strength:
3400V/10 minutes
3515B03101
3X1.5 mm
2
NYY 0.6/1.0 KV Underground Armored Electrical Power Control Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
3 PVC insulated 1.5 mm
2
CL2 wires, cabled together, inner PVC jacket, Served Steel Wire Armor (Rodent Protection) and outer PVC jacket. This cable is officially approved by SII to Israeli Standard 547.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
14.0mm nom.,
Weight:
365kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383,
Dielectric Strength:
3400V/10 minutes
3515C04101
4X1.5 mm
2
NYCY 0.6/1.0 KV Shielded Electrical Control Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
4 Class 2 Insulated wires are cabled together, overall double braid shielded and jacketed.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
12.0mm nom.,
Weight:
250kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1,
Dielectric Strength:
3400V/10 minutes
3515C12101
12X1.5 mm
2
NYCY 0.6/1.0 KV Shielded Electrical Control Cable
Applications:
Low voltage power, Power and control, Outdoor Plant, Underground Installations,
General Construction:
12 PVC insulated 1.5 mm
2
Class 2 wires, cabled together, overall copper braid shielded and PVC jacketed.,
Conductor Cross Section:
1.5mm²,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
16.5mm nom.,
Weight:
465kg/km,
Flamability Rating:
IEC 60332-1,
Dielectric Strength:
3400V/10 minutes
1
2
3
>>>
>>|
Send selected products by email
Hide
Specify email:
Comment:
Terms of Use
|
Privacy Policy
|
Web Development
TELDOR Cables & Systems Ltd. - Ein-Dor, 19335 ISRAEL Tel: +972-4-6770555 Fax: +972-4-6770650