Home
English
|
Русский
|
Español
|
Deutsch
Cables & Systems Ltd.
ABOUT US
Company Profile
Environment
Technologies
Development
General Warranty
Terms and Conditions of Sale
Business Partners
Our Distributors in North America
Our Distributors in Africa
NEWS
Headlines
Press Releases
Events
Announcements
PRODUCT BROCHURES
The BASIC Solution
TM
The GIGA Solution
TM
The GIGA-STAR Solution
TM
The TERA-DOR Solution
TM
The CONTROL Solution
TM
RUS Copper OSP Cables
The Hook-Up Solution
Previous Synergy Products
LD Cable Family
ADSS Cable Family
MU Cable Family
SL Cable Family
MT Cable Family
MC Cable Family
Fiber Specifications
FiberOptic Color Code
QUALITY
QA Program
Teldor's Product Warranty
Certifications
SUPPORT
Designers' Forum
White Papers
Web Site Support
Help with PDF Files
Quotes and RFI
SITE
Site Map
Site Search
Contact Us
CONTACT US
Teldor Departments
Links
Marketing and Sales
User Name:
Password:
Why Register?
Forgotten Password?
Product Families
Computer & LAN
Cat. 3
Cat. 5
Cat. 5e
Cat. 6
Cat. 6
A
Cat. 7
Cat. 7
A
1200 MHz
xDSL
120 Ω E1/T1
IBM-Type 150 Ω
Specialty
FiberOptics
Indoor
Indoor/Outdoor
Outdoor
Tactical
Specialty
Industrial Ethernet & BUS
Industrial Ethernet
CanBUS
ProfiBUS
DeviceNET
InterBUS
FieldBUS-H1
FieldBUS-H2
RS-485/422
RS-232
Specialty
Low Capacitance 2x24/1 AWG F/UTP FR-LSZH
Instrumentation, Control & Signal
300V
300V Shielded
300V Shield+Armor
300V Shield+MB
600V
600V Shielded
600V Shield+Armor
600V Shield+MB
Thermocouples
Fire Alarm & Control
Solid Conductor Control
Specialty
Electronic & Audio
Microphone
Analog A/V
Digital A/V
Electronics
Hook-up
Specialty
Telecom
Switchboard
Outdoor Trunk
Access Trunk
Figure-8
Drop
Specialty
Coax
MIL C-17
MIL TYPES
75 Ω
50 Ω
Specialty
Power
Single Wires
Flexible Cords
0.6/1.0 KV PVC Underground Cables
0.6/1.0 KV XLPE Underground Cables
Heating Wires
Speaker Cables
Specialty
Military & Defense
Ground Forces
Tactical/Rapid Deployment
Shipboard
Hook-Up
Mil/Aero
Specialty
Specialty Cables
Specialty
Hybrid Cables
Product Search:
Advanced Search
SITE SEARCH
Instrumentation, Control & Signal /
600V Shield+Armor
/ Conductors /
16 AWG Singles
Generic P/N
Image
Product Description
PDF
8A6X300101
1x16 AWG XLPE 600V AWG Overall Shielded & Armored Instrumentation Cord
Applications:
Process control industry, Indoor, Outdoor, Class 1 Division 2,
General Construction:
1 wire is cabled together with a drain wire and overall foil shielded and jacketed. A corrugated steel armor followed by an outer jacket complete the cables structure.,
Outer Jacket Material:
FR-PE,
Outer Diameter:
10.5mm nom.,
Weight:
135kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8ANW004101
4x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
4 wires are cabled together, polyester/aluminum foil shielded, inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
14.0mm nom.,
Weight:
300kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8ANW007101
7x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
7 wires are cabled together, polyester/aluminum foil shielded, inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket complete the cable structure.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
16.0mm nom.,
Weight:
395kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8ANW030101
30x16 AWG 600V Shielded and Armored Control Cable
Applications:
Indoor and outdoor, Fixed or portable installation, Control and audio applications,
Applications:
Process control industry, Hazardous areas, Outdoor, Direct burial, Class 1 Division 2,
Applications:
Control applications, Fixed or portable installation, Outdoor or direct burial,
General Construction:
30 - 16 AWG 600V XLPE insulated wires are cabled into a cable core. The Cable core is overall shielded with a polyester/aluminum tape. An inner sheath of FR PVC compound is applied and followed by a Steel Braid Armor (Rodent Protection), an outer sheath of FR PVC compound complete the cable sructure. ,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
28.0mm nom.,
Weight:
1140kg/km,
Flamability Rating:
IEC 60332-3
8ANW0C6104
6x16 AWG 600V XLPE Overall Shielded Armored (SWA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
6 wires are cabled together, polyester/aluminum foil shielded, inner PVC jacket, Steel Wire Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
17.0mm nom.,
Weight:
510kg/km,
Flamability Rating:
IEC 60332-3
8ANW0D6104
6x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
6 wires are cabled together, polyester/aluminum foil shielded, inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
16.0mm nom.,
Weight:
390kg/km,
Flamability Rating:
IEC 60332-3
8B6W007101
7x16 AWG 600V PVC Overall Shielded Armored (SWA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
7 wires are cabled together and foil shielded, an inner PVC jacket followed by Steel Wire Armor (Rodent Protection) and an outer PVC jacket completes the cable structure.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
18.0mm nom.,
Weight:
645kg/km,
Flamability Rating:
IEC 60332-3
8BDW118101
18x16 AWG 600V Overall Shielded Armored Control Cable
Applications:
Process control industry, Short-range low-frequency signals, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
18 wires are cabled together, overall polyester/aluminum foil shielded, inner PVC jacket, Served Steel Wire Armor (Rodent Protection) and outer PVC jacket. The wires are 600 Volts and 105°C rated per MIL-W-16878.,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
20.5mm nom.,
Weight:
860kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8H6W604xxx
4x16 AWG HFFR 600V Shielded & Armored Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Indoor, Outdoor, Class 1 Division 2,
General Construction:
4 - Wires are cabled together and overall foil shielded. An inner jacket followed by a Steel Wire Armor (Rodent Protection) and an outer termite protected jacket complete the cable structure.,
Outer Jacket Material:
HFFR,
Outer Diameter:
14.5mm nom.,
Weight:
425kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8H6W634xxx
34x16 AWG HFFR 600V Shielded & Armored Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Indoor, Outdoor, Class 1 Division 2,
General Construction:
34 - Wires are cabled together and overall foil shielded. An inner jacket followed by a Steel Wire Armor (Rodent Protection) and an outer termite protected jacket complete the cable structure.,
Outer Jacket Material:
HFFR,
Outer Diameter:
29.5mm nom.,
Weight:
1865kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8M6W002xxx
1x2x16 AWG 600V Overall Shielded Instrumentation Cable with Served Wire Armor
Applications:
Process control industry, Hazardous areas, Harsh environments, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
1 overall foil shielded twisted pair is inner jacketed, served with steel wire armor and outer jacketed. ,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
14.0mm nom.,
Weight:
360kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8M6W004101
4x16 AWG 600V Overall Shielded Instrumentation Cable with Served Wire Armor
Applications:
Process control industry, Hazardous areas, Harsh environments, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
4 wires are cabled together with a drain wire and overall polyester/aluminum foil shielded, an inner PVC jacket followed by a served steel wire armor (Rodent Protection) and an outer PVC jacket complete the cable structure. ,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
16mm nom.,
Weight:
515kg/km,
Flamability Rating:
IEC 60332-1
8M6W006101
6x16 AWG 600V Overall Shielded Instrumentation Cable with Served Wire Armor
Applications:
Process control industry, Hazardous areas, Harsh environments, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
6 wires are cabled together with a drain wire and overall polyester/aluminum foil shielded, an inner PVC jacket followed by a served steel wire armor (Rodent Protection) and an outer PVC jacket complete the cable structure. ,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
17.7mm nom.,
Weight:
630kg/km,
Flamability Rating:
IEC 60332-1
8M6W008101
8x16 AWG 600V Overall Shielded Instrumentation Cable with Served Wire Armor
Applications:
Process control industry, Hazardous areas, Harsh environments, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
8 wires are cabled together with a drain wire and overall polyester/aluminum foil shielded, an inner PVC jacket followed by a served steel wire armor (Rodent Protection) and an outer PVC jacket complete the cable structure. ,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
19.0mm nom.,
Weight:
720kg/km,
Flamability Rating:
IEC 60332-1
8M6WF04xxx
4x16 AWG PVC 600V Shielded & Armored Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Indoor, Outdoor, Class 1 Division 2,
General Construction:
4 Wires are cabled together and overall foil shielded. An inner jacket followed by a Steel Wire Armor and an outer jacket complete the cable structure. The cable is made with low smoke & low halogen compounds.,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
15.5mm nom.,
Weight:
455kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8M6WF06xxx
6x16 AWG PVC 600V Shielded & Armored Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Indoor, Outdoor, Class 1 Division 2,
General Construction:
6 Wires are cabled together and overall foil shielded. An inner jacket followed by a Steel Wire Armor and an outer jacket complete the cable structure. The cable is made with low smoke & low halogen compounds.,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
17.0mm nom.,
Weight:
550kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8M6WF08xxx
8x16 AWG PVC 600V Shielded & Armored Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Indoor, Outdoor, Class 1 Division 2,
General Construction:
8 Wires are cabled together and overall foil shielded. An inner jacket followed by a Steel Wire Armor and an outer jacket complete the cable structure. The cable is made with low smoke & low halogen compounds.,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
18.0mm nom.,
Weight:
635kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8M6WF20xxx
20x16 AWG PVC 600V Shielded & Armored Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Indoor, Outdoor, Class 1 Division 2,
General Construction:
20 Wires are cabled together and overall foil shielded. An inner jacket followed by a Steel Wire Armor and an outer jacket complete the cable structure. The cable is made with low smoke & low halogen compounds.,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
25.0mm nom.,
Weight:
1195kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8M8W002xxx
1x2x18 AWG 600V Overall Shielded Instrumentation Cable with Served Wire Armor
Applications:
Process control industry, Hazardous areas, Harsh environments, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
1 overall foil shielded twisted pair is inner jacketed, served with steel wire armor and outer jacketed. ,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
12.5mm nom.,
Weight:
295kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8MNW112101
12x16 AWG 600V Overall Shielded Armored Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Indoor, Outdoor,
General Construction:
12 wires are cabled into a cable core which is overall shielded with a polyester/aluminum tape and then An inner PVC jacket, Steel Wire Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
21.0mm nom.,
Weight:
860kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8MNW117101
17x16 AWG 600V Overall Shielded Armored Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Indoor, Outdoor,
General Construction:
17 wires are cabled into a cable core which is overall shielded with a polyester/aluminum tape . An inner PVC jacket, Steel Wire Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
24.0mm nom.,
Weight:
1070kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
9841630101
30x16 AWG 600V Shielded and Armored Control Cable
Applications:
Indoor and outdoor, Fixed or portable installation, Control and audio applications,
Applications:
Process control industry, Hazardous areas, Outdoor, Direct burial, Class 1 Division 2,
Applications:
Control applications, Fixed or portable installation, Outdoor or direct burial,
General Construction:
The cable contains: 30 - 16 AWG 600V FRXLPE insulated wires cabled into a cable core. Cable core is overall shielded with a polyester/aluminum tape.An inner sheath of FR PVC compound is applied and a Steel Braid Armor (Rodent Protection) is on top of it followed by an outer sheath of FR PVC compound. ,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
28.0mm nom.,
Weight:
1255kg/km,
Flamability Rating:
IEC 60332-3
984A630101
30x16 AWG 600V Shielded and Armored Control Cable
Applications:
Indoor and outdoor, Fixed or portable installation, Control and audio applications,
Applications:
Process control industry,
Applications:
Control applications, Fixed or portable installation, Outdoor or direct burial,
General Construction:
The cable contains: 30 - 16 AWG 600V XLPE insulated wires cabled into a cable core. Cable core is overall shielded with a polyester/aluminum tape.An inner sheath of FR PVC compound is applied and a Steel Braid Armor (Rodent Protection) is on top of it followed by an outer sheath of FR PVC compound. ,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
28.0mm nom.,
Weight:
1140kg/km,
Flamability Rating:
IEC 60332-3
984D630101
30x16 AWG 600V XLPE Overall Shielded and Armored Control Cable
Applications:
Indoor and outdoor, Fixed or portable installation, Control and audio applications,
Applications:
Process control industry, Hazardous areas, Outdoor, Direct burial, Class 1 Division 2,
Applications:
Control applications, Fixed or portable installation, Outdoor or direct burial,
General Construction:
The cable contains: 30 - 16 AWG XLPE insulated wires, cabled together, overall shielded with polyester/aluminum foil. An inner sheath of FR PVC compound is applied and a Steel Braid Armor (Rodent Protection) is on top of it followed by an outer sheath of FR PVC compound. ,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
28.0mm nom.,
Weight:
1180kg/km,
Flamability Rating:
IEC 60332-3