Home English  |  Русский  |  Español  |  Deutsch
User Name:
Password:
Why Register?
Forgotten Password?
Product Families
Computer & LAN
FiberOptics
Industrial Ethernet & BUS
Instrumentation, Control & Signal
Electronic & Audio
Telecom
Coax
Power
Military & Defense
Specialty Cables
Product Search:
Advanced Search


SITE SEARCH
Instrumentation, Control & Signal  /  300V Shield+Armor  /  Conductors  /  Other Conductors
Generic P/N Image Product Description PDF
8561401101 1x2x14 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  overall polyester/aluminum tape shielded pair, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 11.0mm nom., Weight: 245kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
85A1401101 1x2x14 AWG Direct Burial Instrumentation Cable Overall Shielded with Corrugated Steel Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier and corrugated steel armor (Rodent Protection) made of steel tape bonded to  FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 12.5mm nom., Weight: 200kg/km, Flamability Rating: IEC 60332-3 , UL 1581 VW-1
8661401101 1x3x14 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  triad overall polyester/aluminum tape shielded , inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 12.5mm nom., Weight: 335kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761206101 6x2x12 AWG Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 6  pairs are individual shielded with polyester/aluminum tape,  cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 29.0mm nom., Weight: 1590kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761402101 2x2x14 AWG Individual and Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Outdoor, Direct burial, Class 1 Division 2, General Construction: 2 - pairs are individually foil shielded,cabled together and overall foil shielded. An inner jacket followed by steel wire armor (rodent protection) and an outer jacket completes the cable structure., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 19.5mm nom., Weight: 690kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761405101 5x2x14 AWG Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 5 individualy shielded  pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 23.6mm nom., Weight: 1040kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761406101 6x2x14 AWG Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 6 individual shielded  pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 23.0mm nom., Weight: 1040kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761408101 8x2x14 AWG Individual and Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Outdoor, Direct burial, Class 1 Division 2, General Construction: 8 - pairs are individually foil shielded,cabled together and overall foil shielded. An inner jacket followed by steel wire armor (rodent protection) and an outer jacket completes the cable structure., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 27mm nom., Weight: 1515kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761412101 12x2x14 AWG Individual and Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Outdoor, Direct burial, Class 1 Division 2, General Construction: 12 - pairs are individually foil shielded,cabled together and overall foil shielded. An inner jacket followed by steel wire armor (rodent protection) and an outer jacket completes the cable structure., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 32.5mm nom., Weight: 1955kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761416101 16x2x14 AWG Individual and Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Outdoor, Direct burial, Class 1 Division 2, General Construction: 16 - pairs are individually foil shielded,cabled together and overall foil shielded. An inner jacket followed by steel wire armor (rodent protection) and an outer jacket completes the cable structure., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 36mm nom., Weight: 2380kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761424101 24x2x14 AWG Individual and Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Outdoor, Direct burial, Class 1 Division 2, General Construction: 24 Individually shielded twisted pairs are cabled together and overall foil shielded. An inner jacket followed by steel wire armor (rodent protection) and an outer jacket completes the cable structure., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 45.5mm nom., Weight: 3710kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8762212101 12x2x22 AWG Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 12 individual shielded  pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 21.0mm nom., Weight: 780kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8791206101 6x2x12 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 6  pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 28.0mm nom., Weight: 1455kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8791416101 16x2x14 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 16  pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 33.5mm nom., Weight: 2080kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8861406101 6x3x14 AWG Individual and Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 6 polyester/aluminum tape shielded triads are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, Steel Wire Armor (Rodent Protection) and outer PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 27.0mm nom., Weight: 1390kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8861412101 12x3x14 AWG Individual and Overall Shielded and Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 12 polyester/aluminum tape shielded triads are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, Steel Wire Armor (Rodent Protection) and outer PVC jacket., Outer Jacket Material: FR-PVC, Outer Diameter: 34.5mm nom., Weight: 2375kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8891412101 12x3x14 AWG Overall Shielded and Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 12 triads are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, Steel Wire Armor (Rodent Protection) and outer PVC jacket., Outer Jacket Material: FR-PVC, Outer Diameter: 29.0mm nom., Weight: 1830kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8H32M02101 2x2x1.5 mm2 HFFR Individual Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 2  - 1.5 mm2 individual shielded  pairs are cabled together, inner HFFR jacket, served steel  wire  armor (Rodent Protection) and outer HFFR jacket. , Outer Jacket Material: HFFR, Outer Diameter: 18.5mm nom., Weight: 675kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8H32M04101 4x2x1.5 mm2 HFFR Individual Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 4  - 1.5 mm2 individual shielded  pairs are cabled together, inner HFFR jacket, served steel  wire  armor (Rodent Protection) and outer HFFR jacket. , Outer Jacket Material: HFFR, Outer Diameter: 21.5mm nom., Weight: 880kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8N1Q102101 1x2x1.0 mm2 Overall Shielded Instrumentation Cable with Steel Braid Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, Direct burial, Class 1 Division 2, General Construction: 1 - twisted pair, polyester/aluminum tape shielded, inner PVC jacket, served steel  braid  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC -50°C to +105°C rating, Outer Diameter: 10.6mm nom., Weight: 195kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8N1Q103101 1x3x1.0 mm2 Overall Shielded Instrumentation Cable with Steel Braid Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, Direct burial, Class 1 Division 2, General Construction: 1 - triad, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  braid  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC -50°C to +105°C rating, Outer Diameter: 11.0mm nom., Weight: 215kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8N2H006101 6x2x12 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 6  pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner 105°C rated PVC jacket, served steel  wire  armor (Rodent Protection) and outer 105°C rated  PVC jacket. , Outer Jacket Material: FR-PVC -50°C to +105°C rating, Outer Diameter: 28.0mm nom., Weight: 1425kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8N2W103101 3x12 AWG Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Indoor, Outdoor, General Construction: 3 wires are cabled into a cable core which is overall shielded with a polyester/aluminum tape. An inner  sheath of PVC Compound is applied. A Steel Wire Armor (Rodent Protection) followed by an outer sheath of PVC compound is applied on top. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 15.0mm nom., Weight: 465kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8N2W104101 4x12 AWG Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Indoor, Outdoor, General Construction: 4 wires are cabled into a cable core which is overall shielded with a polyester/aluminum tape. An inner  sheath of PVC Compound is applied. A Steel Wire Armor (Rodent Protection) followed by an outer sheath of PVC compound is applied on top. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 16mm nom., Weight: 530kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8N2W105101 5x12 AWG Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Indoor, Outdoor, General Construction: 5 wires are cabled into a cable core which is overall shielded with a polyester/aluminum tape. An inner  sheath of PVC Compound is applied. A Steel Wire Armor (Rodent Protection) followed by an outer sheath of PVC compound is applied on top. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 17mm nom., Weight: 615kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8N4M012101 12x3x14 AWG Individual and Overall Shielded and Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 12 polyester/aluminum tape shielded triads are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, Steel Wire Armor (Rodent Protection) and outer 105°C rated PVC jacket., Outer Jacket Material: FR-PVC -50°C to +105°C rating, Outer Diameter: 34.5mm nom., Weight: 2375kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8N4Q001101 1x3x14 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  triad overall polyester/aluminum tape shielded , inner 105°C rated PVC jacket, served steel  wire  armor (Rodent Protection) and outer 105°C rated  PVC jacket. , Outer Jacket Material: FR-PVC -50°C to +105°C rating, Outer Diameter: 12.5mm nom., Weight: 335kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8N4W108101 8x14 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 8 - 14 AWG single wires,  cabled together, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 17.5mm nom., Weight: 670kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8N4WPU2xxx 2x14 AWG FPLR Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Fire alarm, Indoor, Outdoor, General Construction: 2 - wires are cabled together and overall polyester/aluminum  foil shielded. An inner  jacket followed by a Steel Wire Armor (Rodent Protection) and an outer jacket complete the cable structure. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 12.6mm nom., Weight: 330kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, UL CMR
8X1M008xxx 8x3x1 mm2 XLPE Individual and Overall Shielded, Direct Burial Instrumentation Cable with Steel Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 8 individually foil shielded triads are cabled together and overall foil shielded. An inner PVC jacket followed by a Steel Wire Armor (Rodent Protection) and an outer  jacket complete the cable structure., Conductor Cross Section: 1.0mm², Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 23.0mm nom., Weight: 1010kg/km, Flamability Rating: IEC 60332-3 , IEEE 383

1 2 >>>>>|

Send to email Send selected products by email