Instrumentation, Control & Signal  /  Thermocouples

Filter Search Results By:

Conductors:
Standard:
Insulation Material:
 


Generic P/N Image Product Description PDF
8012X08xxx THERMOCOUPLE EXTENSION CABLE 8x2x20 AWG INDIVIDUAL and OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 8 - 20 AWG PVC insulated thermocouple extension pairs , individual and overall shielded with polyester/aluminum foil and outer PVC jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 12.5mm nom., Weight: 225kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8012X16xxx THERMOCOUPLE EXTENSION CABLE 16x2x20 AWG INDIVIDUAL and OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 16 - 20 AWG PVC insulated thermocouple extension pairs , individual and overall shielded with polyester/aluminum foil and outer PVC jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 18.5mm nom., Weight: 415kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8012X24xxx THERMOCOUPLE EXTENSION CABLE 24x2x20 AWG INDIVIDUAL and OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 24 - 20 AWG PVC insulated thermocouple extension pairs , individual and overall shielded with polyester/aluminum foil and outer PVC jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 21.5mm nom., Weight: 580kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8013X08xxx THERMOCOUPLE EXTENSION CABLE 8x2x18 AWG INDIVIDUAL and OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 8 - 18 AWG PVC insulated thermocouple extension pairs , individual and overall shielded with polyester/aluminum foil and outer PVC jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 14.0mm nom., Weight: 285kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8013X12xxx THERMOCOUPLE EXTENSION CABLE 12x2x18 AWG INDIVIDUAL and OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Indoor, Outdoor, Class 1 Division 2, General Construction: 12 - 18 AWG PVC insulated thermocouple extension pairs , individual and overall shielded with polyester/aluminum foil and outer PVC jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 17.0mm nom., Weight: 400kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8014X02xxx THERMOCOUPLE EXTENSION CABLE 2x2x16 AWG INDIVIDUAL AND OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 2 pairs, PVC insulated thermocouple extension cable,  individual and overall shielded with polyester/aluminum foil and jacketed with  PVC. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type  , Outer Jacket Material: FR-PVC, Outer Diameter: 11.0mm nom., Weight: 155kg/km, Flamability Rating: IEC 60332-3
8014X04xxx THERMOCOUPLE EXTENSION CABLE 4x2x16 AWG INDIVIDUAL and OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 4 pairs, PVC insulated thermocouple extension cable,  individual and overall shielded with polyester/aluminum foil and jacketed with  PVC. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: FR-PVC, Outer Diameter: 12.5mm nom., Weight: 235kg/km, Flamability Rating: IEC 60332-3
8014X08xxx THERMOCOUPLE EXTENSION CABLE 8x2x16 AWG INDIVIDUAL and OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 8 pairs, PVC insulated thermocouple extension cable,  individual and overall shielded with polyester/aluminum foil and jacketed with  PVC. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: FR-PVC, Outer Diameter: 15.0mm nom., Weight: 400kg/km, Flamability Rating: IEC 60332-3
8014X12xxx THERMOCOUPLE EXTENSION CABLE 12x2x16 AWG INDIVIDUAL and OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 12 pairs, PVC insulated thermocouple extension cable,  individual and overall shielded with polyester/aluminum foil and jacketed with  PVC. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: FR-PVC, Outer Diameter: 20.0mm nom., Weight: 590kg/km, Flamability Rating: IEC 60332-3
8014x14xxx 14x2x16 AWG Individuall and Overall Shielded Thermocouple Extension Cable
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 14 Thermocouple extension pairs are individual foil shielded and cabled together with a communication wire. An overall foil shield and jacket complete the cable structure. Replace the fifth character in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 21mm nom., Weight: 665kg/km, Flamability Rating: IEC 60332-3
8014X15xxx THERMOCOUPLE EXTENSION CABLE 15x2x16 AWG INDIVIDUAL and OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 15 pairs, PVC insulated thermocouple extension cable,  individual and overall shielded with polyester/aluminum foil and jacketed with  PVC. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: FR-PVC, Outer Diameter: 22.5mm nom., Weight: 730kg/km, Flamability Rating: IEC 60332-3
8014X24xxx THERMOCOUPLE EXTENSION CABLE 24x2x16 AWG INDIVIDUAL and OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 24 pairs, PVC insulated thermocouple extension cable,  individual and overall shielded with polyester/aluminum foil and jacketed with  PVC. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: FR-PVC, Outer Diameter: 28.0mm nom., Weight: 1075kg/km, Flamability Rating: IEC 60332-3
8014xH4105 4x2x16 AWG Individual & Overall Shielded HFFR Thermocouple Extension Cable
Applications: Process control industry, Thermocouple extension, Indoor, Class 1 Division 2, General Construction: 4 Individually shielded thermocouple extension pairs are cabled together with a drain wire, overall foil shielded and jacketed. Replace the fifth character in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: HFFR, Outer Diameter: 16.7mm nom., Weight: 325kg/km, Flamability Rating: IEC 60332-1
8014xH8xxx 8x2x16 AWG Individual & Overall Shielded HFFR Thermocouple Extension Cable
Applications: Process control industry, Thermocouple extension, Indoor, Class 1 Division 2, General Construction: 4 Individually shielded thermocouple extension pairs are cabled together with a drain wire, overall foil shielded and jacketed. Replace the fifth character in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: HFFR, Outer Diameter: 24.0mm nom., Weight: 570kg/km, Flamability Rating: IEC 60332-1
8022X16xxx Direct Burial Thermocouple Extension Cable 16x2x20 AWG Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 16 PVC insulated thermocouple extension pairs, cabled together, overall shelded with polyester/aluminum foil, inner PVC jacket, moisture barrier of aluminum tape bonded to FR PE jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: FR-PE, Outer Diameter: 20.5mm nom., Weight: 460kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8023X16xxx Direct Burial Thermocouple Extension Cable 16x2x18 AWG Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 16 PVC insulated thermocouple extension pairs, cabled together, overall shelded with polyester/aluminum foil, inner PVC jacket, moisture barrier of aluminum tape bonded to FR PE jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: FR-PE, Outer Diameter: 21.5mm nom., Weight: 565kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8054X01xxx DIRECT BURIAL THERMOCOUPLE EXTENSION CABLE 1x2x16 AWG OVERALL SHIELDED WITH MOISTURE BARRIER
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: PVC insulated thermocouple extension pair, overall shelded with polyester/aluminum foil, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket. Replace the fifth digint in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX, 6 fot SX thermocouple type Color code for conductors and jaket per ANCI MC96.1, Outer Jacket Material: FR-PE, Outer Diameter: 10.0mm nom., Weight: 107kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8073X16xxx THERMOCOUPLE EXTENSION CABLE 16x2x18 AWG OVERALL SHIELD WITH SERVED WIRE ARMOR
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 16 PVC insulated thermocouple extension pairs, overall shelded with polyester/aluminum foil, inner PVC jacket, Steel Wire Armor (Rodent Protection) and outer jacket. Replace the fifth digint in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX Color code for conductors and jaket per ANCI MC96.1, Outer Jacket Material: FR-PVC, Outer Diameter: 22.5mm nom., Weight: 970kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
80743H1101 DIRECT BURIAL ARMORED THERMOCOUPLE TYPE KX EXTENSION CABLE 1x2x16 AWG OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: PVC insulated thermocouple extension pair, overall shelded with polyester/aluminum foil, inner HFFR jacket, Steel Wire Armor (Rodent Protection) and outer HFFR  jacket. Color code for conductors and jaket per ANCI MC96.1, Outer Jacket Material: HFFR, Outer Diameter: 10.5mm nom., Weight: 240kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
80743T1105 DIRECT BURIAL ARMORED THERMOCOUPLE TYPE KX EXTENSION CABLE 1x2x16 AWG OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 1 Thermocouple extension twisted pair is overall foil shielded, inner jacketed, Steel Wire Armored and jacketed., Outer Jacket Material: XL-HFFR, Outer Diameter: 10.5mm nom., Weight: 225kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
80743X1101 DIRECT BURIAL ARMORED THERMOCOUPLE TYPE KX EXTENSION CABLE 1x2x16 AWG OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 1 Thermocouple extension twisted pair is overall foil shielded, inner jacketed, Steel Wire Armored and jacketed., Outer Jacket Material: XL-HFFR, Outer Diameter: 10.5mm nom., Weight: 235kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8074x01108 DIRECT BURIAL ARMORED THERMOCOUPLE EXTENSION CABLE 1x2x16 AWG OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 1 Thermocouple extension twisted pair is overall foil shielded, inner PVC jacketed, Steel Wire Armored and jacketed. Replace the fifth character in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX, Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 10.5mm nom., Weight: 230kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8084X02xxx THERMOCOUPLE EXTENSION ARMORED CABLE 2x2x16 AWG INDIVIDUAL and OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 2 pairs, PVC insulated thermocouple extension cable,  individual and overall shielded with polyester/aluminum foil. Inner PVC jacket, Steel Wire Armor (Rodent Protection) and outer PVC jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 15.5mm nom., Weight: 420kg/km, Flamability Rating: IEC 60332-3
8084X20xxx THERMOCOUPLE EXTENSION ARMORED CABLE 20x2x16 AWG INDIVIDUAL and OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 20 pairs, PVC insulated thermocouple extension cable,  individual and overall shielded with polyester/aluminum foil. Inner PVC jacket, Steel Wire Armor (Rodent Protection) and outer PVC jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 32.0mm nom., Weight: 1940kg/km, Flamability Rating: IEC 60332-3
8092X00xxx THERMOCOUPLE EXTENSION CABLE 1x2x20 AWG OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: PVC insulated thermocouple extension pair, overall shelded with polyester/aluminum foil and jacketed with an FR-PVC compound. Replace the fifth digint in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX Color code for conductors and jaket per ANCI MC96.1, Outer Jacket Material: FR-PVC, Outer Diameter: 5.2mm nom., Weight: 36kg/km, Flamability Rating: IEC 60331, UL 1581 VW-1
8092X08xxx THERMOCOUPLE EXTENSION CABLE 8x2x20 AWG OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 8 pairs, PVC insulated thermocouple extension cable,  overall shielded with polyester/aluminum foil and jacketed with  PVC. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1, Outer Jacket Material: FR-PVC, Outer Diameter: 11.5mm nom., Weight: 185kg/km, Flamability Rating: IEC 60332-3
8092X16xxx THERMOCOUPLE EXTENSION CABLE 16x2x20 AWG OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 16 pairs, PVC insulated thermocouple extension cable,  overall shelded with polyester/aluminum foil and jacketed with  PVC. Replace the fifth digint in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jaket per ANCI MC96.1, Outer Jacket Material: FR-PVC, Outer Diameter: 16.0mm nom., Weight: 330kg/km, Flamability Rating: IEC 60332-3
8092xH0xxx THERMOCOUPLE EXTENSION CABLE 1x2x20 AWG 600V OVERALL SHIELDED HFFR
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: HFFR insulated thermocouple extension pair, overall shielded with polyester/aluminum foil and jacketed with an HFFR compound. Replace the fifth digint in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX, Outer Jacket Material: HFFR, Outer Diameter: 7.5mm nom., Weight: 70kg/km, Flamability Rating: IEC 60332-3
8093X00xxx THERMOCOUPLE EXTENSION CABLE 1x2x18 AWG OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: PVC insulated thermocouple extension pair, overall shelded with polyester/aluminum foil and jacketed with an FR-PVC compound. Replace the fifth digint in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX Color code for conductors and jaket per ANCI MC96.1, Outer Jacket Material: FR-PVC, Outer Diameter: 5.5mm nom., Weight: 45kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8093X04xxx THERMOCOUPLE EXTENSION CABLE 4x2x18 AWG OVERALL SHIELDED
Applications: Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2, General Construction: 4 PVC insulated thermocouple extension pairs, overall shelded with polyester/aluminum foil and jacketed with an FR-PVC compound. Replace the fifth digint in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX Color code for conductors and jaket per ANCI MC96.1, Outer Jacket Material: FR-PVC, Outer Diameter: 10.5mm nom., Weight: 150kg/km, Flamability Rating: IEC 60332-3

1 2 >>>>>|

Send to email Send selected products by email