Home
English
|
Русский
|
Español
|
Deutsch
|
Français
Cables & Systems Ltd.
ABOUT US
Company Profile
Environment
Technologies
Development
General Warranty
Terms and Conditions of Sale
Business Partners
Our Distributors in North America
Our Distributors in Africa
NEWS
Headlines
Press Releases
Events
Announcements
PRODUCT BROCHURES
The BASIC Solution
TM
The GIGA Solution
TM
The GIGA-STAR Solution
TM
The TERA-DOR Solution
TM
The CONTROL Solution
TM
RUS Copper OSP Cables
The Hook-Up Solution
Previous Synergy Products
LD Cable Family
ADSS Cable Family
MU Cable Family
SL Cable Family
MT Cable Family
MC Cable Family
Fiber Specifications
FiberOptic Color Code
QUALITY
QA Program
Teldor's Product Warranty
Certifications
SUPPORT
Designers' Forum
White Papers
Web Site Support
Help with PDF Files
Quotes and RFI
SITE
Site Map
Site Search
Contact Us
CONTACT US
Teldor Departments
Links
Marketing and Sales
User Name:
Password:
Why Register?
Forgotten Password?
Product Families
Computer & LAN
Cat. 3
Cat. 5
Cat. 5e
Cat. 6
Cat. 6
A
Cat. 7
Cat. 7
A
1200 MHz
xDSL
120 Ω E1/T1
IBM-Type 150 Ω
Specialty
FiberOptics
Indoor
Indoor/Outdoor
Outdoor
Tactical
Specialty
Industrial Ethernet & BUS
Industrial Ethernet
CanBUS
ProfiBUS
DeviceNET
InterBUS
FieldBUS-H1
FieldBUS-H2
RS-485/422
RS-232
Specialty
Low Capacitance 2x24/1 AWG F/UTP FR-LSZH
Instrumentation, Control & Signal
300V
300V Shielded
300V Shield+Armor
300V Shield+MB
600V
600V Shielded
600V Shield+Armor
600V Shield+MB
Thermocouples
Fire Alarm & Control
Solid Conductor Control
Specialty
Electronic & Audio
Microphone
Analog A/V
Digital A/V
Electronics
Hook-up
Specialty
Telecom
Switchboard
Outdoor Trunk
Access Trunk
Figure-8
Drop
Specialty
Coax
MIL C-17
MIL TYPES
75 Ω
50 Ω
Specialty
Power
Single Wires
Flexible Cords
0.6/1.0 KV PVC Underground Cables
0.6/1.0 KV XLPE Underground Cables
Heating Wires
Speaker Cables
Specialty
Military & Defense
Ground Forces
Tactical/Rapid Deployment
Shipboard
Hook-Up
Mil/Aero
Specialty
Specialty Cables
Specialty
Hybrid Cables
Product Search:
Advanced Search
SITE SEARCH
Instrumentation, Control & Signal /
Thermocouples
Filter Search Results By:
Conductors:
Select
16 AWG Singles
18 AWG Singles
20 AWG Singles
16 AWG Pairs
18 AWG Pairs
20 AWG Pairs
16 AWG Triads
18 AWG Triads
20 AWG Triads
Other Conductors
Standard:
Select
Class I Div. 2
BS 5308
ANSI 96.1
Indoor Fire Alarm
Outdoor Fire Alarm
Specialty
Insulation Material:
Select
PVC Insulation
PE Insulation
XLPE Insulation
LSZH Insulation
ETFE Insulation
Generic P/N
Image
Product Description
PDF
8012X08xxx
THERMOCOUPLE EXTENSION CABLE 8x2x20 AWG INDIVIDUAL and OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
8 - 20 AWG PVC insulated thermocouple extension pairs , individual and overall shielded with polyester/aluminum foil and outer PVC jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
12.5mm nom.,
Weight:
225kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8012X16xxx
THERMOCOUPLE EXTENSION CABLE 16x2x20 AWG INDIVIDUAL and OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
16 - 20 AWG PVC insulated thermocouple extension pairs , individual and overall shielded with polyester/aluminum foil and outer PVC jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
18.5mm nom.,
Weight:
415kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8012X24xxx
THERMOCOUPLE EXTENSION CABLE 24x2x20 AWG INDIVIDUAL and OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
24 - 20 AWG PVC insulated thermocouple extension pairs , individual and overall shielded with polyester/aluminum foil and outer PVC jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
21.5mm nom.,
Weight:
580kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8013X08xxx
THERMOCOUPLE EXTENSION CABLE 8x2x18 AWG INDIVIDUAL and OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
8 - 18 AWG PVC insulated thermocouple extension pairs , individual and overall shielded with polyester/aluminum foil and outer PVC jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
14.0mm nom.,
Weight:
285kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8013X12xxx
THERMOCOUPLE EXTENSION CABLE 12x2x18 AWG INDIVIDUAL and OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Indoor, Outdoor, Class 1 Division 2,
General Construction:
12 - 18 AWG PVC insulated thermocouple extension pairs , individual and overall shielded with polyester/aluminum foil and outer PVC jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
17.0mm nom.,
Weight:
400kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8014X02xxx
THERMOCOUPLE EXTENSION CABLE 2x2x16 AWG INDIVIDUAL AND OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
2 pairs, PVC insulated thermocouple extension cable, individual and overall shielded with polyester/aluminum foil and jacketed with PVC. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type ,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
11.0mm nom.,
Weight:
155kg/km,
Flamability Rating:
IEC 60332-3
8014X04xxx
THERMOCOUPLE EXTENSION CABLE 4x2x16 AWG INDIVIDUAL and OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
4 pairs, PVC insulated thermocouple extension cable, individual and overall shielded with polyester/aluminum foil and jacketed with PVC. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
12.5mm nom.,
Weight:
235kg/km,
Flamability Rating:
IEC 60332-3
8014X08xxx
THERMOCOUPLE EXTENSION CABLE 8x2x16 AWG INDIVIDUAL and OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
8 pairs, PVC insulated thermocouple extension cable, individual and overall shielded with polyester/aluminum foil and jacketed with PVC. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
15.0mm nom.,
Weight:
400kg/km,
Flamability Rating:
IEC 60332-3
8014X12xxx
THERMOCOUPLE EXTENSION CABLE 12x2x16 AWG INDIVIDUAL and OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
12 pairs, PVC insulated thermocouple extension cable, individual and overall shielded with polyester/aluminum foil and jacketed with PVC. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
20.0mm nom.,
Weight:
590kg/km,
Flamability Rating:
IEC 60332-3
8014x14xxx
14x2x16 AWG Individuall and Overall Shielded Thermocouple Extension Cable
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
14 Thermocouple extension pairs are individual foil shielded and cabled together with a communication wire. An overall foil shield and jacket complete the cable structure. Replace the fifth character in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
21mm nom.,
Weight:
665kg/km,
Flamability Rating:
IEC 60332-3
8014X15xxx
THERMOCOUPLE EXTENSION CABLE 15x2x16 AWG INDIVIDUAL and OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
15 pairs, PVC insulated thermocouple extension cable, individual and overall shielded with polyester/aluminum foil and jacketed with PVC. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
22.5mm nom.,
Weight:
730kg/km,
Flamability Rating:
IEC 60332-3
8014X24xxx
THERMOCOUPLE EXTENSION CABLE 24x2x16 AWG INDIVIDUAL and OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
24 pairs, PVC insulated thermocouple extension cable, individual and overall shielded with polyester/aluminum foil and jacketed with PVC. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
28.0mm nom.,
Weight:
1075kg/km,
Flamability Rating:
IEC 60332-3
8014xH4105
4x2x16 AWG Individual & Overall Shielded HFFR Thermocouple Extension Cable
Applications:
Process control industry, Thermocouple extension, Indoor, Class 1 Division 2,
General Construction:
4 Individually shielded thermocouple extension pairs are cabled together with a drain wire, overall foil shielded and jacketed. Replace the fifth character in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
HFFR,
Outer Diameter:
16.7mm nom.,
Weight:
325kg/km,
Flamability Rating:
IEC 60332-1
8014xH8xxx
8x2x16 AWG Individual & Overall Shielded HFFR Thermocouple Extension Cable
Applications:
Process control industry, Thermocouple extension, Indoor, Class 1 Division 2,
General Construction:
4 Individually shielded thermocouple extension pairs are cabled together with a drain wire, overall foil shielded and jacketed. Replace the fifth character in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
HFFR,
Outer Diameter:
24.0mm nom.,
Weight:
570kg/km,
Flamability Rating:
IEC 60332-1
8022X16xxx
Direct Burial Thermocouple Extension Cable 16x2x20 AWG Overall Shielded with Moisture Barrier
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Direct burial, Class 1 Division 2,
General Construction:
16 PVC insulated thermocouple extension pairs, cabled together, overall shelded with polyester/aluminum foil, inner PVC jacket, moisture barrier of aluminum tape bonded to FR PE jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
FR-PE,
Outer Diameter:
20.5mm nom.,
Weight:
460kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8023X16xxx
Direct Burial Thermocouple Extension Cable 16x2x18 AWG Overall Shielded with Moisture Barrier
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Direct burial, Class 1 Division 2,
General Construction:
16 PVC insulated thermocouple extension pairs, cabled together, overall shelded with polyester/aluminum foil, inner PVC jacket, moisture barrier of aluminum tape bonded to FR PE jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
FR-PE,
Outer Diameter:
21.5mm nom.,
Weight:
565kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8054X01xxx
DIRECT BURIAL THERMOCOUPLE EXTENSION CABLE 1x2x16 AWG OVERALL SHIELDED WITH MOISTURE BARRIER
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
PVC insulated thermocouple extension pair, overall shelded with polyester/aluminum foil, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket. Replace the fifth digint in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX, 6 fot SX thermocouple type Color code for conductors and jaket per ANCI MC96.1,
Outer Jacket Material:
FR-PE,
Outer Diameter:
10.0mm nom.,
Weight:
107kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8073X16xxx
THERMOCOUPLE EXTENSION CABLE 16x2x18 AWG OVERALL SHIELD WITH SERVED WIRE ARMOR
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
16 PVC insulated thermocouple extension pairs, overall shelded with polyester/aluminum foil, inner PVC jacket, Steel Wire Armor (Rodent Protection) and outer jacket. Replace the fifth digint in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX Color code for conductors and jaket per ANCI MC96.1,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
22.5mm nom.,
Weight:
970kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
80743H1101
DIRECT BURIAL ARMORED THERMOCOUPLE TYPE KX EXTENSION CABLE 1x2x16 AWG OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
PVC insulated thermocouple extension pair, overall shelded with polyester/aluminum foil, inner HFFR jacket, Steel Wire Armor (Rodent Protection) and outer HFFR jacket. Color code for conductors and jaket per ANCI MC96.1,
Outer Jacket Material:
HFFR,
Outer Diameter:
10.5mm nom.,
Weight:
240kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
80743T1105
DIRECT BURIAL ARMORED THERMOCOUPLE TYPE KX EXTENSION CABLE 1x2x16 AWG OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
1 Thermocouple extension twisted pair is overall foil shielded, inner jacketed, Steel Wire Armored and jacketed.,
Outer Jacket Material:
XL-HFFR,
Outer Diameter:
10.5mm nom.,
Weight:
225kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
80743X1101
DIRECT BURIAL ARMORED THERMOCOUPLE TYPE KX EXTENSION CABLE 1x2x16 AWG OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
1 Thermocouple extension twisted pair is overall foil shielded, inner jacketed, Steel Wire Armored and jacketed.,
Outer Jacket Material:
XL-HFFR,
Outer Diameter:
10.5mm nom.,
Weight:
235kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8074x01108
DIRECT BURIAL ARMORED THERMOCOUPLE EXTENSION CABLE 1x2x16 AWG OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
1 Thermocouple extension twisted pair is overall foil shielded, inner PVC jacketed, Steel Wire Armored and jacketed. Replace the fifth character in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
10.5mm nom.,
Weight:
230kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8084X02xxx
THERMOCOUPLE EXTENSION ARMORED CABLE 2x2x16 AWG INDIVIDUAL and OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
2 pairs, PVC insulated thermocouple extension cable, individual and overall shielded with polyester/aluminum foil. Inner PVC jacket, Steel Wire Armor (Rodent Protection) and outer PVC jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
15.5mm nom.,
Weight:
420kg/km,
Flamability Rating:
IEC 60332-3
8084X20xxx
THERMOCOUPLE EXTENSION ARMORED CABLE 20x2x16 AWG INDIVIDUAL and OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Direct burial, Class 1 Division 2,
General Construction:
20 pairs, PVC insulated thermocouple extension cable, individual and overall shielded with polyester/aluminum foil. Inner PVC jacket, Steel Wire Armor (Rodent Protection) and outer PVC jacket. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
32.0mm nom.,
Weight:
1940kg/km,
Flamability Rating:
IEC 60332-3
8092X00xxx
THERMOCOUPLE EXTENSION CABLE 1x2x20 AWG OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
PVC insulated thermocouple extension pair, overall shelded with polyester/aluminum foil and jacketed with an FR-PVC compound. Replace the fifth digint in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX Color code for conductors and jaket per ANCI MC96.1,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
5.2mm nom.,
Weight:
36kg/km,
Flamability Rating:
IEC 60331, UL 1581 VW-1
8092X08xxx
THERMOCOUPLE EXTENSION CABLE 8x2x20 AWG OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
8 pairs, PVC insulated thermocouple extension cable, overall shielded with polyester/aluminum foil and jacketed with PVC. Replace the fifth digit in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jacket per ANCI MC96.1,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
11.5mm nom.,
Weight:
185kg/km,
Flamability Rating:
IEC 60332-3
8092X16xxx
THERMOCOUPLE EXTENSION CABLE 16x2x20 AWG OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
16 pairs, PVC insulated thermocouple extension cable, overall shelded with polyester/aluminum foil and jacketed with PVC. Replace the fifth digint in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX thermocouple type Color code for conductors and jaket per ANCI MC96.1,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
16.0mm nom.,
Weight:
330kg/km,
Flamability Rating:
IEC 60332-3
8092xH0xxx
THERMOCOUPLE EXTENSION CABLE 1x2x20 AWG 600V OVERALL SHIELDED HFFR
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
HFFR insulated thermocouple extension pair, overall shielded with polyester/aluminum foil and jacketed with an HFFR compound. Replace the fifth digint in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX,
Outer Jacket Material:
HFFR,
Outer Diameter:
7.5mm nom.,
Weight:
70kg/km,
Flamability Rating:
IEC 60332-3
8093X00xxx
THERMOCOUPLE EXTENSION CABLE 1x2x18 AWG OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
PVC insulated thermocouple extension pair, overall shelded with polyester/aluminum foil and jacketed with an FR-PVC compound. Replace the fifth digint in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX Color code for conductors and jaket per ANCI MC96.1,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
5.5mm nom.,
Weight:
45kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8093X04xxx
THERMOCOUPLE EXTENSION CABLE 4x2x18 AWG OVERALL SHIELDED
Applications:
Process control industry, Hazardous areas, Thermocouple extension, Harsh environments, Class 1 Division 2,
General Construction:
4 PVC insulated thermocouple extension pairs, overall shelded with polyester/aluminum foil and jacketed with an FR-PVC compound. Replace the fifth digint in TELDOR P/N with: 1 - for EX, 3 for KX, 4 for RX, 8 for JX, 9 for TX Color code for conductors and jaket per ANCI MC96.1,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
10.5mm nom.,
Weight:
150kg/km,
Flamability Rating:
IEC 60332-3
1