Home English  |  Русский  |  Español  |  Deutsch
User Name:
Password:
Why Register?
Forgotten Password?
Product Families
Computer & LAN
FiberOptics
Industrial Ethernet & BUS
Instrumentation, Control & Signal
Electronic & Audio
Telecom
Coax
Power
Military & Defense
Specialty Cables
Product Search:
Advanced Search


SITE SEARCH
Instrumentation, Control & Signal  /  600V Shield+MB

Filter Search Results By:

Conductors:
Standard:
Insulation Material:
 


Generic P/N Image Product Description PDF
8A6E301101 1x3x16 AWG 600V XLPE Overall Shielded Instrumentation Cable with Moisture Barrier
Applications: Process control industry, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 1 individually shielded  twisted triad covered with Inner PVC Jacket , moisture barriered bonded to an outer PE Jacket ., Outer Jacket Material: PE, Outer Diameter: 13.4mm nom., Weight: 190kg/km, Flamability Rating: IEC 60332-1
8AN10A1101 1x2x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 1 individual shielded  twisted pair with inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer  PVC jacket., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 13.0mm nom., Weight: 245kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8AN60A1101 1x3x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 1 individual shielded  twisted triad with inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer  PVC jacket., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 13.5mm nom., Weight: 270kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8ANC302101 2x2x16 AWG 600V XLPE Direct Burial Instrumentation Cable Individual and Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 2 individual shielded  pairs are cabled together overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 19.5mm nom., Weight: 310kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8BMT305101 5x18 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 5 wires cabled together, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket. The wires are  600 Volts and  105°C rated per MIL-W-16878., Outer Jacket Material: FR-PE, Outer Diameter: 11.5mm nom., Weight: 160kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8DBA301xxx 2x12 AWG PE 600V Overall Shielded Instrumentation Cable with Moisture Barrier
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, Direct burial, General Construction: 2 wires are cabled together, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 15.0mm nom., Weight: 235kg/km, Flamability Rating: IEC 60331, UL 1581 VW-1
8DBE301101 1x3x12 AWG PE 600V Overall Shielded Instrumentation Cable with Moisture Barrier
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, Direct burial, General Construction: 3 wires are cabled together, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 15.5mm nom., Weight: 280kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8DCC8S2xxx 2x2x14 AWG PE 600V Overall Shielded Instrumentation Cable with Moisture Barrier
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, Direct burial, General Construction: 2 pairs are cabled together, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 20.5mm nom., Weight: 410kg/km, Flamability Rating: IEC 60331, UL 1581 VW-1
8LMC312101 12x2x18 AWG Direct Burial Instrumentation Cable Individual and Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 12 individual shielded  pairs are cabled together, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier made of aluminum tape bonded to  FR PE jacket. The wires are  600 Volts and  105°C rated per MIL-W-16878., Outer Jacket Material: FR-PE, Outer Diameter: 24.5mm nom., Weight: 650kg/km, Flamability Rating: IEC 60331
8M3A301101 1x2x1.5 600V Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1-1.5 mm2 PVC insulated twisted pair, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 10.7mm nom., Weight: 130kg/km, Flamability Rating: IEC 60331
8M3E301101 1x3x1.5 600V Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1-1.5 mm2 PVC insulated twisted triad, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 11.0mm nom., Weight: 155kg/km, Flamability Rating: IEC 60331
8M6T306101 6x16 AWG 600V Overall Shielded Instrumentation Cable with Moisture Barrier
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, Direct burial, General Construction: 6 wires are cabled together, overall shielded with a polyester/aluminum tape, sheathed  with an inner PVC compound Jacket.  A moisture barrier of bonded  aluminum tape is put  in close contact with the outer FR PE sheath .  , Outer Jacket Material: FR-PE, Outer Diameter: 15.5mm nom., Weight: 295kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8M8A301101 1x2x18 AWG 600V Overall Shielded Instrumentation Cable with Moisture Barier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 - 18 AWG twisted pair, overalll polyester/aluminum tape shielded, inner PVC jacket, moisture barier made of  outer FRPE jacket bonded to heavy-duty aluminum tape. , Outer Jacket Material: FR-PVC, Outer Diameter: 11.5mm nom., Weight: 135kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8M8C307101 7x2x18 AWG 600V Individual and Overall Shielded Instrumentation Cable with Moisture Barier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 7 - 18 AWG twisted pairs, individial and overalll polyester/aluminum tape shielded, inner PVC jacket, moisture barier made of  outer FRPE jacket bonded to heavy-duty aluminum tape. , Outer Jacket Material: FR-PVC, Outer Diameter: 24mm nom., Weight: 550kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8M8F303101 3x3x18 AWG 600V Individual and Overall Shielded Instrumentation Cable with Moisture Barier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 3 - 18 AWG twisted triads, individial and overalll polyester/aluminum tape shielded, inner PVC jacket, moisture barier made of  outer FRPE jacket bonded to heavy-duty aluminum tape. , Outer Jacket Material: FR-PVC, Outer Diameter: 20mm nom., Weight: 380kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8M8F312101 12x3x18 AWG 600V Individual and Overall Shielded Instrumentation Cable with Moisture Barier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 12 - 18 AWG twisted triads, individial and overalll polyester/aluminum tape shielded, inner PVC jacket, moisture barier made of  outer FRPE jacket bonded to heavy-duty aluminum tape. , Outer Jacket Material: FR-PVC, Outer Diameter: 32.5mm nom., Weight: 1090kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
9842302101 2x2x1.5 mm 2 Direct Burial Instrumentation Cable with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: Direct burial instrumentetion cable for traffic control 2 - 1.5 mm2 pairs are cabled together with filling, elements, inner PVC jacket, moisture barrier made of aluminum tape bonded to FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 14.5mm nom., Weight: 200kg/km, Flamability Rating: IEC 60332-1
9842304101 4x2x1.5 mm 2 Direct Burial Instrumentation Cable with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: Direct burial instrumentetion cable for traffic control 4 - 1.5 mm2 pairs are cabled together. Jacket  consists of aluminum tape bonded to FR PE jacket (moisture barrier)., Outer Jacket Material: FR-PE, Outer Diameter: 16.5mm nom., Weight: 250kg/km, Flamability Rating: IEC 60332-1


Send to email Send selected products by email