Generic P/N Image Product Description PDF
8A4X312101 12x14 AWGXLPE 600V Overall Shielded Instrumentation Cable With corrugated Steel Armor
Applications: Process control industry, Indoor, Outdoor, General Construction: 12 wires are cabled together, overall foil shielded and jacketed. A corrugated steel armor and an outer jacket complete the cables structure., Outer Jacket Material: PE, Outer Diameter: 22.5mm nom., Weight: 645kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8A5H001101 1x2x2.5 mm2 XLPE Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  overall polyester/aluminum tape shielded pair, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 13.5mm nom., Weight: 360kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8A660A1101 3x16 AWG XLPE 600V Overall Shielded and Armored (SBA) Control Cable
Applications: Process control industry, Short-range low-frequency signals, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 3 wires are cabled together, overall polyester/aluminum foil shielded. Inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 13.5mm nom., Weight: 270kg/km, Flamability Rating: IEC 60332-3
8A6M0A7101 7x3x16 AWG XLPE 600V Individual and Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Direct burial, Class 1 Division 2, General Construction: 7 triads are  individual polyester/aluminum tape shielded, cabled together, overall polyester/aluminum tape shielded. Inner PVC jacket,  Steel Braid Armor (Rodent Protection)  and outer  PVC jacket., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 27.0mm nom., Weight: 965kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8A6QA01101 3x16 AWG XLPE 600V Overall Shielded and Armored (SWA) Control Cable
Applications: Process control industry, Short-range low-frequency signals, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 3 wires are cabled together, overall polyester/aluminum foil shielded. Inner PVC jacket, Served Steel Wire Armor (Rodent Protection) and outer PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 13.5mm nom., Weight: 355kg/km, Flamability Rating: IEC 60332-3
8A6X300101 1x16 AWG XLPE 600V AWG Overall Shielded & Armored Instrumentation Cord
Applications: Process control industry, Indoor, Outdoor, Class 1 Division 2, General Construction: 1 wire is cabled together with a drain wire and overall foil shielded and jacketed. A corrugated steel armor followed by an outer jacket complete the cables structure., Outer Jacket Material: FR-PE, Outer Diameter: 10.5mm nom., Weight: 135kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8A6X301101 1x2x16 AWG XLPE 600V AWG Overall Shielded & Armored Instrumentation Cable
Applications: Process control industry, Indoor, Outdoor, Class 1 Division 2, General Construction: 2 wires are cabled together, overall foil shielded and jacketed. A corrugated steel armor followed by an outer jacket complete the cables structure., Outer Jacket Material: FR-PE, Outer Diameter: 13.0mm nom., Weight: 190kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8A87108101 8x3x18 AWG XLPE 600V Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 8 individual shielded  triads are cabled togetheroverall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 28.5mm nom., Weight: 1340kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8AN10A1101 1x2x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 1 individual shielded  twisted pair with inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer  PVC jacket., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 13.0mm nom., Weight: 245kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8AN60A1101 1x3x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 1 individual shielded  twisted triad with inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer  PVC jacket., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 13.5mm nom., Weight: 270kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8ANJ006101 6x2x16 AWG 600V XLPE Individual and Overall Shielded Armored (SBA) Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 6 individual polyester/aluminum shielded pairs, cabled together, overall polyester/aluminum foil shielded,  inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer  PVC jacket., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 24.5mm nom., Weight: 770kg/km, Flamability Rating: IEC 60332-3
8ANJ014101 14x2x16 AWG 600V XLPE Individual and Overall Shielded Armored (SBA) Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 14 individual polyester/aluminum shielded pairs, cabled together, overall polyester/aluminum foil shielded,  inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer  PVC jacket., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 34.5mm nom., Weight: 1380kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8ANM007101 7x3x16 AWG 600V XLPE Individual and Overall Shielded Armored (SBA) Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 7 individual polyester/aluminum shielded triads, cabled together, overall polyester/aluminum foil shielded,  inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer  PVC jacket., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 26.5mm nom., Weight: 945kg/km, Flamability Rating: IEC 60332-3
8ANW004101 4x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 4 wires are cabled together, polyester/aluminum foil shielded,  inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer  PVC jacket., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 14.0mm nom., Weight: 300kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8ANW006101 6x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 6 wires are cabled together, polyester/aluminum foil shielded,  inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer  PVC jacket., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 16.0mm nom., Weight: 390kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8ANW007101 7x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 7 wires are cabled together, polyester/aluminum foil shielded,  inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer  PVC jacket complete the cable structure., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 16.0mm nom., Weight: 395kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8ANW0C6104 6x16 AWG 600V XLPE Overall Shielded Armored (SWA) Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 6 wires are cabled together, polyester/aluminum foil shielded,  inner PVC jacket, Steel Wire Armor (Rodent Protection) and outer  PVC jacket., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 17.0mm nom., Weight: 510kg/km, Flamability Rating: IEC 60332-3
8ANW0D6104 6x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 6 wires are cabled together, polyester/aluminum foil shielded,  inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer  PVC jacket., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 16.0mm nom., Weight: 390kg/km, Flamability Rating: IEC 60332-3
8B2W102104 2x12 AWG 600V Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  overall polyester/aluminum tape shielded pair, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 17.5mm nom., Weight: 570kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8B2W112104 12x12 AWG 600V Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 12 wires, cabled together,  overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 30mm nom., Weight: 1730kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8B6W007101 7x16 AWG 600V PVC Overall Shielded Armored (SWA) Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 7 wires are cabled together and  foil shielded, an inner PVC jacket  followed by Steel Wire Armor (Rodent Protection) and an outer   PVC jacket completes the cable structure., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 18.0mm nom., Weight: 645kg/km, Flamability Rating: IEC 60332-3
8BDW118101 18x16 AWG 600V Overall Shielded Armored Control Cable
Applications: Process control industry, Short-range low-frequency signals, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 18 wires are cabled together, overall polyester/aluminum foil shielded, inner  PVC jacket, Served Steel Wire Armor (Rodent Protection) and outer PVC jacket. The wires are  600 Volts and  105°C rated per MIL-W-16878., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 20.5mm nom., Weight: 860kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8D6I1A4101 4x2x16 AWG 600V Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 4 individual shielded PE insulated twisted  pairs are cabled together, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 24.0mm nom., Weight: 890kg/km, Flamability Rating: IEC 60332-1
8H1HM02101 2x2x1.0 mm2 HFFR FTP Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 2 -1.0 mm2 twisted pairs, cabled together, overall polyester/aluminum tape shielded, inner HFFR jacket, Served Steel Wire Armor (Rodent Protection) and outer HFFR jacket. , Outer Jacket Material: HFFR, Outer Diameter: 17.5mm nom., Weight: 560kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8H1HM04101 4x2x1.0 mm2 HFFR FTP Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 4 -1.0 mm2 twisted pairs, cabled together, overall polyester/aluminum tape shielded, inner HFFR jacket, Served Steel Wire Armor (Rodent Protection) and outer HFFR jacket. , Outer Jacket Material: HFFR, Outer Diameter: 18.0mm nom., Weight: 635kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8H1HM25101 25x2x1.0 mm2 HFFR FTP Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 25 -1.0 mm2 twisted pairs, cabled together, overall polyester/aluminum tape shielded, inner HFFR jacket, Served Steel Wire Armor (Rodent Protection) and outer HFFR jacket. , Outer Jacket Material: HFFR, Outer Diameter: 32.5mm nom., Weight: 2000kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8H4I602xxx 2x2x14 AWG HFFR 600V Individually Shielded & Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, Class 1 Division 2, General Construction: 2  - twisted pairs are individually foil shielded and cabled together. An inner jacket followed by a Steel Wire Armor (Rodent Protection) and  an outer termite protected jacket complete the cable structure., Outer Jacket Material: HFFR, Outer Diameter: 23.0mm nom., Weight: 1000kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8H4V604xxx 4x14 AWG HFFR 600V Unshielded Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, Class 1 Division 2, General Construction: 4  - Wires  are cabled together and jacketed. A Steel Wire Armor (Rodent Protection) and  an outer termite protected jacket complete the cable structure., Outer Jacket Material: HFFR, Outer Diameter: 16.0mm nom., Weight: 515kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8H4V606xxx 6x14 AWG HFFR 600V Unshielded Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, Class 1 Division 2, General Construction: 6  - Wires  are cabled together and jacketed. A Steel Wire Armor (Rodent Protection) and  an outer termite protected jacket complete the cable structure., Outer Jacket Material: HFFR, Outer Diameter: 18.5mm nom., Weight: 770kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8H4V608xxx 8x14 AWG HFFR 600V Unshielded Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, Class 1 Division 2, General Construction: 8 - Wires  are cabled together and jacketed. A Steel Wire Armor (Rodent Protection) and  an outer termite protected jacket complete the cable structure., Outer Jacket Material: HFFR, Outer Diameter: 20.0mm nom., Weight: 860kg/km, Flamability Rating: IEC 60332-3 , IEEE 383