Home
English
|
Русский
|
Español
|
Deutsch
|
Français
Cables & Systems Ltd.
ABOUT US
Company Profile
Environment
Technologies
Development
General Warranty
Terms and Conditions of Sale
Business Partners
Our Distributors in North America
Our Distributors in Africa
NEWS
Headlines
Press Releases
Events
Announcements
PRODUCT BROCHURES
The BASIC Solution
TM
The GIGA Solution
TM
The GIGA-STAR Solution
TM
The TERA-DOR Solution
TM
The CONTROL Solution
TM
RUS Copper OSP Cables
The DNV Marine Solution
The Hook-Up Solution
Previous Synergy Products
LD Cable Family
ADSS Cable Family
MU Cable Family
SL Cable Family
MT Cable Family
MC Cable Family
Fiber Specifications
FiberOptic Color Code
QUALITY
QA Program
Teldor's Product Warranty
Certifications
SUPPORT
Designers' Forum
White Papers
Web Site Support
Help with PDF Files
Quotes and RFI
SITE
Site Map
Site Search
Contact Us
CONTACT US
Teldor Departments
Links
Marketing and Sales
User Name:
Password:
Why Register?
Forgotten Password?
Product Families
Computer & LAN
Cat. 3
Cat. 5
Cat. 5e
Cat. 6
Cat. 6
A
Cat. 7
Cat. 7
A
1200 MHz
xDSL
120 Ω E1/T1
IBM-Type 150 Ω
Specialty
FiberOptics
Indoor
Indoor/Outdoor
Outdoor
Tactical
Specialty
Industrial Ethernet & BUS
Industrial Ethernet
CanBUS
ProfiBUS
DeviceNET
InterBUS
FieldBUS-H1
FieldBUS-H2
RS-485/422
RS-232
Specialty
Low Capacitance 2x24/1 AWG F/UTP FR-LSZH
Instrumentation, Control & Signal
300V
300V Shielded
300V Shield+Armor
300V Shield+MB
600V
600V Shielded
600V Shield+Armor
600V Shield+MB
Thermocouples
Fire Alarm & Control
Solid Conductor Control
Specialty
Electronic & Audio
Microphone
Analog A/V
Digital A/V
Electronics
Hook-up
Specialty
Telecom
Switchboard
Outdoor Trunk
Access Trunk
Figure-8
Drop
Specialty
Coax
MIL C-17
MIL TYPES
75 Ω
50 Ω
Specialty
Power
Single Wires
Flexible Cords
0.6/1.0 KV PVC Underground Cables
0.6/1.0 KV XLPE Underground Cables
Heating Wires
Speaker Cables
Specialty
Military & Defense
Ground Forces
Tactical/Rapid Deployment
Shipboard
Hook-Up
Mil/Aero
Specialty
Specialty Cables
Specialty
Hybrid Cables
Product Search:
Advanced Search
SITE SEARCH
Instrumentation, Control & Signal /
600V Shield+Armor
Filter Search Results By:
Conductors:
Select
16 AWG Singles
18 AWG Singles
20 AWG Singles
16 AWG Pairs
18 AWG Pairs
20 AWG Pairs
16 AWG Triads
18 AWG Triads
20 AWG Triads
Other Conductors
Standard:
Select
Class I Div. 2
BS 5308
ANSI 96.1
Indoor Fire Alarm
Outdoor Fire Alarm
Specialty
Insulation Material:
Select
PVC Insulation
PE Insulation
XLPE Insulation
LSZH Insulation
ETFE Insulation
Generic P/N
Image
Product Description
PDF
8A4X312101
12x14 AWGXLPE 600V Overall Shielded Instrumentation Cable With corrugated Steel Armor
Applications:
Process control industry, Indoor, Outdoor,
General Construction:
12 wires are cabled together, overall foil shielded and jacketed. A corrugated steel armor and an outer jacket complete the cables structure.,
Outer Jacket Material:
PE,
Outer Diameter:
22.5mm nom.,
Weight:
645kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8A5H001101
1x2x2.5 mm
2
XLPE Overall Shielded Instrumentation Cable with Served Wire Armor
Applications:
Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2,
General Construction:
1 overall polyester/aluminum tape shielded pair, inner PVC jacket, served steel wire armor (Rodent Protection) and outer PVC jacket. ,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
13.5mm nom.,
Weight:
360kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8A660A1101
3x16 AWG XLPE 600V Overall Shielded and Armored (SBA) Control Cable
Applications:
Process control industry, Short-range low-frequency signals, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
3 wires are cabled together, overall polyester/aluminum foil shielded. Inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
13.5mm nom.,
Weight:
270kg/km,
Flamability Rating:
IEC 60332-3
8A6M0A7101
7x3x16 AWG XLPE 600V Individual and Overall Shielded Armored Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Direct burial, Class 1 Division 2,
General Construction:
7 triads are individual polyester/aluminum tape shielded, cabled together, overall polyester/aluminum tape shielded. Inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
27.0mm nom.,
Weight:
965kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8A6QA01101
3x16 AWG XLPE 600V Overall Shielded and Armored (SWA) Control Cable
Applications:
Process control industry, Short-range low-frequency signals, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
3 wires are cabled together, overall polyester/aluminum foil shielded. Inner PVC jacket, Served Steel Wire Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
13.5mm nom.,
Weight:
355kg/km,
Flamability Rating:
IEC 60332-3
8A6X300101
1x16 AWG XLPE 600V AWG Overall Shielded & Armored Instrumentation Cord
Applications:
Process control industry, Indoor, Outdoor, Class 1 Division 2,
General Construction:
1 wire is cabled together with a drain wire and overall foil shielded and jacketed. A corrugated steel armor followed by an outer jacket complete the cables structure.,
Outer Jacket Material:
FR-PE,
Outer Diameter:
10.5mm nom.,
Weight:
135kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8A6X301101
1x2x16 AWG XLPE 600V AWG Overall Shielded & Armored Instrumentation Cable
Applications:
Process control industry, Indoor, Outdoor, Class 1 Division 2,
General Construction:
2 wires are cabled together, overall foil shielded and jacketed. A corrugated steel armor followed by an outer jacket complete the cables structure.,
Outer Jacket Material:
FR-PE,
Outer Diameter:
13.0mm nom.,
Weight:
190kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8A87108101
8x3x18 AWG XLPE 600V Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications:
Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2,
General Construction:
8 individual shielded triads are cabled togetheroverall polyester/aluminum tape shielded, inner PVC jacket, served steel wire armor (Rodent Protection) and outer PVC jacket. ,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
28.5mm nom.,
Weight:
1340kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8AN10A1101
1x2x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
1 individual shielded twisted pair with inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
13.0mm nom.,
Weight:
245kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8AN60A1101
1x3x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
1 individual shielded twisted triad with inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
13.5mm nom.,
Weight:
270kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8ANJ006101
6x2x16 AWG 600V XLPE Individual and Overall Shielded Armored (SBA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
6 individual polyester/aluminum shielded pairs, cabled together, overall polyester/aluminum foil shielded, inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
24.5mm nom.,
Weight:
770kg/km,
Flamability Rating:
IEC 60332-3
8ANJ014101
14x2x16 AWG 600V XLPE Individual and Overall Shielded Armored (SBA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
14 individual polyester/aluminum shielded pairs, cabled together, overall polyester/aluminum foil shielded, inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
34.5mm nom.,
Weight:
1380kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8ANM007101
7x3x16 AWG 600V XLPE Individual and Overall Shielded Armored (SBA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
7 individual polyester/aluminum shielded triads, cabled together, overall polyester/aluminum foil shielded, inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
26.5mm nom.,
Weight:
945kg/km,
Flamability Rating:
IEC 60332-3
8ANW004101
4x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
4 wires are cabled together, polyester/aluminum foil shielded, inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
14.0mm nom.,
Weight:
300kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8ANW006101
6x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
6 wires are cabled together, polyester/aluminum foil shielded, inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
16.0mm nom.,
Weight:
390kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8ANW007101
7x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
7 wires are cabled together, polyester/aluminum foil shielded, inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket complete the cable structure.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
16.0mm nom.,
Weight:
395kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8ANW0C6104
6x16 AWG 600V XLPE Overall Shielded Armored (SWA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
6 wires are cabled together, polyester/aluminum foil shielded, inner PVC jacket, Steel Wire Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
17.0mm nom.,
Weight:
510kg/km,
Flamability Rating:
IEC 60332-3
8ANW0D6104
6x16 AWG 600V XLPE Overall Shielded Armored (SBA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
6 wires are cabled together, polyester/aluminum foil shielded, inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
16.0mm nom.,
Weight:
390kg/km,
Flamability Rating:
IEC 60332-3
8B2W102104
2x12 AWG 600V Overall Shielded Instrumentation Cable with Served Wire Armor
Applications:
Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2,
General Construction:
1 overall polyester/aluminum tape shielded pair, inner PVC jacket, served steel wire armor (Rodent Protection) and outer PVC jacket. ,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
17.5mm nom.,
Weight:
570kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8B2W112104
12x12 AWG 600V Overall Shielded Instrumentation Cable with Served Wire Armor
Applications:
Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2,
General Construction:
12 wires, cabled together, overall polyester/aluminum tape shielded, inner PVC jacket, served steel wire armor (Rodent Protection) and outer PVC jacket. ,
Outer Jacket Material:
FR-PVC,
Outer Diameter:
30mm nom.,
Weight:
1730kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8B6W007101
7x16 AWG 600V PVC Overall Shielded Armored (SWA) Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
7 wires are cabled together and foil shielded, an inner PVC jacket followed by Steel Wire Armor (Rodent Protection) and an outer PVC jacket completes the cable structure.,
Outer Jacket Material:
FR-PVC ST2 per IEC 60502,
Outer Diameter:
18.0mm nom.,
Weight:
645kg/km,
Flamability Rating:
IEC 60332-3
8BDW118101
18x16 AWG 600V Overall Shielded Armored Control Cable
Applications:
Process control industry, Short-range low-frequency signals, Indoor, Outdoor, Direct burial, Class 1 Division 2,
General Construction:
18 wires are cabled together, overall polyester/aluminum foil shielded, inner PVC jacket, Served Steel Wire Armor (Rodent Protection) and outer PVC jacket. The wires are 600 Volts and 105°C rated per MIL-W-16878.,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
20.5mm nom.,
Weight:
860kg/km,
Flamability Rating:
IEC 60332-1, UL 1581 VW-1
8D6I1A4101
4x2x16 AWG 600V Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications:
Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2,
General Construction:
4 individual shielded PE insulated twisted pairs are cabled together, inner PVC jacket, served steel wire armor (Rodent Protection) and outer PVC jacket. ,
Outer Jacket Material:
UV resistant FR-PVC,
Outer Diameter:
24.0mm nom.,
Weight:
890kg/km,
Flamability Rating:
IEC 60332-1
8H1HM02101
2x2x1.0 mm
2
HFFR FTP Instrumentation Cable with Served Wire Armor
Applications:
Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2,
General Construction:
2 -1.0 mm
2
twisted pairs, cabled together, overall polyester/aluminum tape shielded, inner HFFR jacket, Served Steel Wire Armor (Rodent Protection) and outer HFFR jacket. ,
Outer Jacket Material:
HFFR,
Outer Diameter:
17.5mm nom.,
Weight:
560kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8H1HM04101
4x2x1.0 mm
2
HFFR FTP Instrumentation Cable with Served Wire Armor
Applications:
Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2,
General Construction:
4 -1.0 mm
2
twisted pairs, cabled together, overall polyester/aluminum tape shielded, inner HFFR jacket, Served Steel Wire Armor (Rodent Protection) and outer HFFR jacket. ,
Outer Jacket Material:
HFFR,
Outer Diameter:
18.0mm nom.,
Weight:
635kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8H1HM25101
25x2x1.0 mm
2
HFFR FTP Instrumentation Cable with Served Wire Armor
Applications:
Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2,
General Construction:
25 -1.0 mm
2
twisted pairs, cabled together, overall polyester/aluminum tape shielded, inner HFFR jacket, Served Steel Wire Armor (Rodent Protection) and outer HFFR jacket. ,
Outer Jacket Material:
HFFR,
Outer Diameter:
32.5mm nom.,
Weight:
2000kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8H4I602xxx
2x2x14 AWG HFFR 600V Individually Shielded & Armored Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Indoor, Outdoor, Class 1 Division 2,
General Construction:
2 - twisted pairs are individually foil shielded and cabled together. An inner jacket followed by a Steel Wire Armor (Rodent Protection) and an outer termite protected jacket complete the cable structure.,
Outer Jacket Material:
HFFR,
Outer Diameter:
23.0mm nom.,
Weight:
1000kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8H4V604xxx
4x14 AWG HFFR 600V Unshielded Armored Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Indoor, Outdoor, Class 1 Division 2,
General Construction:
4 - Wires are cabled together and jacketed. A Steel Wire Armor (Rodent Protection) and an outer termite protected jacket complete the cable structure.,
Outer Jacket Material:
HFFR,
Outer Diameter:
16.0mm nom.,
Weight:
515kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8H4V606xxx
6x14 AWG HFFR 600V Unshielded Armored Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Indoor, Outdoor, Class 1 Division 2,
General Construction:
6 - Wires are cabled together and jacketed. A Steel Wire Armor (Rodent Protection) and an outer termite protected jacket complete the cable structure.,
Outer Jacket Material:
HFFR,
Outer Diameter:
18.5mm nom.,
Weight:
770kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383
8H4V608xxx
8x14 AWG HFFR 600V Unshielded Armored Instrumentation Cable
Applications:
Process control industry, Hazardous areas, Indoor, Outdoor, Class 1 Division 2,
General Construction:
8 - Wires are cabled together and jacketed. A Steel Wire Armor (Rodent Protection) and an outer termite protected jacket complete the cable structure.,
Outer Jacket Material:
HFFR,
Outer Diameter:
20.0mm nom.,
Weight:
860kg/km,
Flamability Rating:
IEC 60332-3 , IEEE 383