Instrumentation, Control & Signal  /  600V Shielded

Filter Search Results By:

Conductors:
Standard:
Insulation Material:
 


Generic P/N Image Product Description PDF
4T00690101 2 Fiber loose tube + 3x16 AWG Braid Shielded Hybrid Cable
Applications: Control and audio applications, Indoor applications, Low-frequency data applications, General Construction: Hybrid cable contains: 3 - 16 AWG XLHFFR insulated wires. 2 - 62.5 µm  Fiber optics in a loose tube. The wires and the loose tube are cabled together, Overall braided with an ARAMID strength member followed by a Tinned Copper braid . A low surface adhesion (MAT) POLYURETHANE jacket completes the cable structure., Tube Diameter: 3.1mm nom., Outer Jacket Material: PU, Outer Diameter: 11.0mm nom., Weight: 180kg/km, Flamability Rating: IEC 60332-1
4T00700101 4 Fiber sm in 2 loose tubes + 2x16 AWG Armored Hybrid Cable
Applications: Control and audio applications, Indoor applications, Low-frequency data applications, General Construction: Hybrid cable contains: 2 - 16 AWG XLHFFR insulated wires. 4 -Singlemode (G.652) color coded optical fibers, each with a 250µm outer diameter. Two optical fibers are contained each in 2 loose tubes filled with thixotropic gel. The wires and the loose tubes are cabled together with ARAMID strength members  around a central ARAMID strength member, galvannized steel wire armor (rodent protection) followed by a POLYURETHANE jacket completes the cable structure., Tube Diameter: 3.1mm nom., Outer Jacket Material: PU, Outer Diameter: 10.2mm nom., Weight: 150kg/km, Flamability Rating: IEC 60332-1
4TA0002101 9x2x12/63 AWG XLPE OBS FR-PU
Applications: Hazardous areas, Harsh environments, Indoor, Outdoor, General Construction: 9 Twisted pairs are cabled together, overall braid shielded and jacketed., Outer Jacket Material: FR-PU, Outer Diameter: 28.5mm nom., Weight: 1000kg/km
8702436101 36x(2x24 AWG) XL-HFFR Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Maritime Environment, General Construction: 36 Unshielded twisted pairs are cabled together, overall foil shielded and jacketed. The jacket material has an excellent resistance to chemicals, oil and fuel., Outer Jacket Material: XL-HFFR, Outer Diameter: 14.5mm nom., Weight: 315kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8A11601101 1x2x1.0 mm2 XLPE 600V Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Short-range low-frequency signals, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire overall aluminum-foil shielded and PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 7.5mm nom., Weight: 70kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8A2P002101 2x12 AWG XLPE 600V Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair,  overall polyester/aluminum tape shielded and outer PVC compound  jacketed. , Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 11.0mm nom., Weight: 155kg/km, Flamability Rating: IEC 60332-1
8A2P003101 3x12 AWG XLPE 600V Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted triad,  overall polyester/aluminum tape shielded and outer PVC jacketed. , Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 11.5mm nom., Weight: 200kg/km, Flamability Rating: IEC 60332-1
8A2P004101 4x12 AWG XLPE 600V Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 4 - 12 AWG wires are cabled together,  overall polyester/aluminum tape shielded and outer PVC jacketed. , Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 12.5mm nom., Weight: 250kg/km, Flamability Rating: IEC 60332-1
8A2P006101 6x12 AWG XLPE 600V Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 6 wires are cabled together,  overall polyester/aluminum tape shielded and outer PVC jacketed. , Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 15.7mm nom., Weight: 390kg/km, Flamability Rating: IEC 60332-1
8A2P012xxx 12x12 AWG XLPE 600V Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 12 wires are cabled together, overall foil shielded and jacketed. , Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 21.0mm nom., Weight: 685kg/km, Flamability Rating: IEC 60332-1
8A2PH04xxx 4x12 AWG XLPE 600V Overall Shielded Instrumentation Cable
Applications: Process control industry, Short-range low-frequency signals, Indoor, Outdoor, Class 1 Division 2, General Construction: 4 Wires are cabled together, overall foil shielded and double jacketed. , Outer Jacket Material: XL-HFFR, Outer Diameter: 15.6mm nom., Weight: 380kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
8A2PH12xxx 12x12 AWG XLPE OFS 600/1000V Instrumentation Cable
Applications: Process control industry, Short-range low-frequency signals, Indoor, Outdoor, Class 1 Division 2, General Construction: 12 Wires are cabled together, overall foil shielded and jacketed. , Outer Jacket Material: XL-HFFR, Outer Diameter: 21.0mm nom., Weight: 730kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8A31002101 2x2x1.5 mm2 600V Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Short-range low-frequency signals, Class 1 Division 2, General Construction: 2 twisted pairs, cabled together overall polyester/aluminum foil shielded  and PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 13.5mm nom., Weight: 180kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8A31008101 8x2x1.5 mm2 600V Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Short-range low-frequency signals, Class 1 Division 2, General Construction: 8 twisted pairs, cabled together overall polyester/aluminum foil shielded  and PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 21.0mm nom., Weight: 485kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8A37M03xxx 3x3x1.5 mm2 XLPE 600V Individual and Overall Shielded Instrumentation Cable
Applications: Process control industry, Short-range low-frequency signals, Class 1 Division 2, General Construction: 3 - individually foil shielded twisted triads are cabled together, overall foil shielded and jacketed., Outer Jacket Material: HFFR, Outer Diameter: 17.2mm nom., Weight: 365kg/km, Flamability Rating: IEC 60332-3
8A37M12xxx 12x3x1.5 mm2 XLPE 600V Individual and Overall Shielded Instrumentation Cable
Applications: Process control industry, Short-range low-frequency signals, Class 1 Division 2, General Construction: 12 - individually foil shielded twisted triads are cabled together, overall foil shielded and jacketed., Outer Jacket Material: HFFR, Outer Diameter: 30.0mm nom., Weight: 1150kg/km, Flamability Rating: IEC 60332-3
8A4P002104 2x14 AWG XLPE 600V Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 -  twisted pair,  overall polyester/aluminum tape shielded and outer PVC jacketed. , Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 9.5mm nom., Weight: 115kg/km, Flamability Rating: IEC 60332-1
8A4P003101 3x14 AWG XLPE 600V Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 -  twisted triad,  overall polyester/aluminum tape shielded and outer PVC jacketed. , Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 10.0mm nom., Weight: 145kg/km, Flamability Rating: IEC 60332-1
8A4P004101 4x14 AWG XLPE 600V Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 4 wires are cabled together,  overall polyester/aluminum tape shielded and outer PVC jacketed. , Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 11.0mm nom., Weight: 175kg/km, Flamability Rating: IEC 60332-1
8A4P007101 7x14 AWG XLPE 600V Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 7 wires are cabled together,  overall polyester/aluminum tape shielded and outer PVC jacketed. , Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 13.0mm nom., Weight: 265kg/km, Flamability Rating: IEC 60332-1
8A4PH04xxx 4x14 AWG XLPE 600V Overall Shielded Instrumentation Cable
Applications: Process control industry, Short-range low-frequency signals, Indoor, Outdoor, Class 1 Division 2, General Construction: 4 Wires are cabled together, overall foil shielded and double jacketed. , Outer Jacket Material: XL-HFFR, Outer Diameter: 14.0mm nom., Weight: 285kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
8A4PH07xxx 7x14 AWG XLPE 600V Overall Shielded Instrumentation Cable
Applications: Process control industry, Short-range low-frequency signals, Indoor, Outdoor, Class 1 Division 2, General Construction: 7 Wires are cabled together, overall foil shielded and double jacketed. , Outer Jacket Material: XL-HFFR, Outer Diameter: 16.0mm nom., Weight: 385kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, Dielectric Strength: 3400V/10 minutes
8A57M03xxx 3x3x2.5 mm2 XLPE 600V Individual and Overall Shielded Instrumentation Cable
Applications: Process control industry, Short-range low-frequency signals, Class 1 Division 2, General Construction: 3 - individually foil shielded twisted triads are cabled together, overall foil shielded and jacketed., Outer Jacket Material: HFFR, Outer Diameter: 19.2mm nom., Weight: 485kg/km, Flamability Rating: IEC 60332-3
8A57M12xxx 12x3x2.5 mm2 XLPE 600V Individual and Overall Shielded Instrumentation Cable
Applications: Process control industry, Short-range low-frequency signals, Class 1 Division 2, General Construction: 12 - individually foil shielded twisted triads are cabled together, overall foil shielded and jacketed., Outer Jacket Material: HFFR, Outer Diameter: 34.0mm nom., Weight: 1610kg/km, Flamability Rating: IEC 60332-3
8A61001101 2x16 AWG XLPE 600V Overall Shielded Control Cable
Applications: Process control industry, Short-range low-frequency signals, Indoor, Outdoor, General Construction: 2 wires are cabled together, overall polyester/aluminum foil shielded  and PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 9.0mm nom., Weight: 95kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8A610A1101 2x16 AWG XLPE 600V Overall Shielded and Armored (SBA) Control Cable
Applications: Process control industry, Short-range low-frequency signals, Indoor, Outdoor, Direct burial, Class 1 Division 2, General Construction: 2 wires are cabled together, overall polyester/aluminum foil shielded. Inner PVC jacket, Steel Braid Armor (Rodent Protection) and outer PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 13.0mm nom., Weight: 245kg/km, Flamability Rating: IEC 60332-3
8A61101101 2x16 AWG XLPE 600V Overall Shielded Control Cable
Applications: Process control industry, Short-range low-frequency signals, Indoor, Outdoor, General Construction: 2 wires are cabled together, overall polyester/aluminum foil shielded  and PVC jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 9.0mm nom., Weight: 95kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8A61301101 2x16 AWG XLPE 600V Overall Shielded Control Cable
Applications: Process control industry, Short-range low-frequency signals, Indoor, Outdoor, General Construction: 2 wires are cabled together, overall polyester/aluminum foil shielded  and FRPE jacketed., Outer Jacket Material: FR-PE, Outer Diameter: 9.0mm nom., Weight: 82kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8A61601101 2x16 AWG XLPE 600V Overall Shielded Control Cable
Applications: Process control industry, Short-range low-frequency signals, Indoor, Outdoor, General Construction: 2 wires are cabled together, overall polyester/aluminum foil shielded  and HFFR jacketed., Outer Jacket Material: HFFR, Outer Diameter: 9.0mm nom., Weight: 102kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8A63002101 2x2x16 AWG XLPE 600V Individual and Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 2 pairs are  individual polyester/aluminum tape shielded, cabled together, overall polyester/aluminum tape shielded and with a PVC compound jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 15.0mm nom., Weight: 200kg/km, Flamability Rating: IEC 60332-3 , IEEE 383