Home English  |  Русский  |  Español  |  Deutsch
User Name:
Password:
Why Register?
Forgotten Password?
Product Families
Computer & LAN
FiberOptics
Industrial Ethernet & BUS
Instrumentation, Control & Signal
Electronic & Audio
Telecom
Coax
Power
Military & Defense
Specialty Cables
Product Search:
Advanced Search


SITE SEARCH
Instrumentation, Control & Signal  /  600V

Filter Search Results By:

Conductors:
Standard:
Insulation Material:
 


Generic P/N Image Product Description PDF
3331103xxx 3x10 AWG 600V Flexible Control Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 3 - flexible wires (class 5 per IEC 60228) are cabled together and  jacketed. The cable provides excellent resistance to abrasion, oils and chemicals., Outer Jacket Material: FR-PU, Outer Diameter: 13.5mm nom., Weight: 305kg/km, Flamability Rating: IEC 60332-1, Dielectric Strength: 2000V/15 minutes
3331105xxx 5x10 AWG 600V Flexible Control Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 5 - flexible wires (class 5 per IEC 60228) are cabled together and  jacketed. The cable provides excellent resistance to abrasion, oils and chemicals., Outer Jacket Material: FR-PU, Outer Diameter: 16.5mm nom., Weight: 460kg/km, Flamability Rating: IEC 60332-1, Dielectric Strength: 2000V/15 minutes
3331604xxx 4x16 AWG 600V Flexible Control Cable
Applications: Low voltage power, Power and control, Outdoor Plant, Underground Installations, General Construction: 4 - flexible wires (class 5 per IEC 60228) are cabled together and  jacketed. The cable provides excellent resistance to abrasion, oils and chemicals., Outer Jacket Material: FR-PU, Outer Diameter: 10mm nom., Weight: 137kg/km, Flamability Rating: IEC 60332-1, Dielectric Strength: 2000V/15 minutes
4T00710107 8x62.5/125 µm + 4x12 AWG Double Jacketed Hybrid Cable
Applications: Control and audio applications, Indoor and outdoor use, Low-frequency data applications, Military-Defense, Portable use and repeated flexing, General Construction: Hybrid cable contains: 4 - 12 AWG  wires 8 - 62.5/125 µm Tactical cable  (TELDOR P/N F60080823B) . The wires are cabled together with filling elements  around the tactical cable. An inner jacket is applied, followed by multiple ends of served Aramid yarn. A low surface adhesion (MAT)  jacket completes the cable structure., Outer Jacket Material: FR-PU, Outer Diameter: 20mm nom., Weight: 485kg/km, Flamability Rating: IEC 60332-1
5F12502104 2x2.5 mm2 Control Cable
Applications: Short-range low-frequency signals, Fire alarm, Indoor, Applications: , General Construction: The cable contains one 2.5 mm2 PVC insulated twisted pair with outer PVC jacket., Outer Jacket Material: FR-PVC, Outer Diameter: 8.1mm nom., Weight: 90kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
6440822xxx 8 AWG HFFR 600V Flexible Conductor
Applications: Portable and repeated flexing, Hook-up, Indoor, Control applications, Applications: Process control industry, Short-range low-frequency signals, Indoor, General Construction: One flexible wire is insulated., Outer Diameter: 6.0mm nom., Weight: 95kg/km, Flamability Rating: UL 1581 VW-1
6441220xxx 12 AWG HFFR Flexible Conductor 600 V
Applications: Portable and repeated flexing, Hook-up, Indoor, Control applications, Applications: Indoor, General Construction: 12 - AWG HFFR insulated flexible wire, Outer Diameter: 4.00mm nom., Weight: 43kg/km, Flamability Rating: UL 1581 VW-1
6441632xxx 16 AWG HFFR Flexible Conductor 600 V
Applications: Portable and repeated flexing, Hook-up, Indoor, Control applications, Applications: Indoor, General Construction: 16 - AWG HFFR insulated flexible wire, Outer Diameter: 3.1mm nom., Weight: 21.0kg/km, Flamability Rating: UL 1581 VW-1
7127771101 6x18 AWG + 2x14 AWG Unshielded Control Cable
Applications: Multiple/Rapid deployment, Applications: Audio-frequency signals, Indoor and outdoor, Portable, indoor applications, Control and audio applications, Control applications, Applications: Control applications, Fixed or portable installation, Indoor and outdoor use, General Construction: The cable contains: 6 - 18 AWG PVC insulated conductors 2 - 12 AWG PVC insulated conductors Cabled together and jacketed with PVC., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 8.7mm nom., Weight: 175kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8298A02101 1x2x16 AWG ETFE Unshielded Instrumentation Cable
Applications: Short-range low-frequency signals, Outdoor, Audio, General Construction: 1 ETFE insulated twisted pair, jacketed with XLHFFR compound., Outer Jacket Material: XL-HFFR, Outer Diameter: 5.7mm nom., Weight: 45kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8A09104101 4x10 AWG XLPE 600V Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, General Construction: 4-10 AWG XLPE insulated wires, cabled together and PVC jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 14.0mm nom., Weight: 330kg/km, Flamability Rating: IEC 60332-1
8A091A3101 3x10 AWG XLPE 600V Armored Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, Direct burial, General Construction: 3-10 AWG XLPE insulated wires, cabled together,  inner PVC jacket, Served Wire Armor (Rodent Protection) and outer PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 17.0mm nom., Weight: 560kg/km, Flamability Rating: IEC 60332-3
8A09M03101 3x10 AWG XLPE 600V HFFR Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, General Construction: 3-10 AWG XLPE insulated wires, cabled together and HFFR jacketed., Outer Jacket Material: HFFR, Outer Diameter: 12.5mm nom., Weight: 315kg/km, Flamability Rating: IEC 60332-3
8A0P003101 3x10 AWG XLPE Shielded 600V Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, Class 1 Division 2, General Construction: 3-10 AWG XLPE insulated conductors, cabled together, polyester/aluminum foil shielded anf PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 12.5mm nom., Weight: 320kg/km, Flamability Rating: IEC 60332-1
8A0P004101 4x10 AWG XLPE Shielded 600V Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, Class 1 Division 2, General Construction: 4-10 AWG XLPE insulated conductors, cabled together, polyester/aluminum foil shielded anf PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 14.5mm nom., Weight: 380kg/km, Flamability Rating: IEC 60332-1
8A0P012101 12x10 AWG XLPE Shielded 600V Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, Class 1 Division 2, General Construction: 12 wires are cabled together, Overall foil shielded and jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 22.5mm nom., Weight: 945kg/km, Flamability Rating: IEC 60332-3
8A0R304101 4x10 AWG XLPE 600V Direct Burial Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, Direct burial, General Construction: 4-10 AWG XLPE insulated wires, cabled together, inner PVC jacket and outer FRPE jacket bonded to aluminum tape (Moisture Barier)., Outer Jacket Material: FR-PE, Outer Diameter: 17.5mm nom., Weight: 415kg/km, Flamability Rating: IEC 60332-1
8A0V006101 (6+1) x10 AWG XLPE 600V Armored Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, Direct burial, General Construction: 6-10 AWG XLPE insulated wires + 1-10 AWG drain wire , cabled together, inner PVC jacket, Served Steel Wire Armor (Rodent Protection), and then an  outer PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 24.0mm nom., Weight: 1150kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8A0V604101 4x10 AWG XLPE/HFFR 600V Armored Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, Direct burial, General Construction: 4-10 AWG XLPE insulated wires, cabled together, inner HFFR jacket, Served Steel Wire Armor (Rodent Protection)  outer HFFR jacket., Outer Jacket Material: HFFR, Outer Diameter: 19.5mm nom., Weight: 810kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8A0VM05101 5x10 AWG XLPE/HFFR 600V Armored Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, Direct burial, General Construction: 5-10 AWG XLPE insulated wires, cabled together, inner HFFR jacket, Served Steel Wire Armor (Rodent Protection)  outer HFFR jacket., Outer Jacket Material: HFFR, Outer Diameter: 20.5mm nom., Weight: 940kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8A29002101 2x12 AWG XLPE 600V Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, General Construction: 2 wires are cabled together and jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 11.0mm nom., Weight: 140kg/km, Flamability Rating: IEC 60331
8A29004101 4x12 AWG XLPE 600V PVC Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, General Construction: 4-12 AWG XLPE insulated wires are cabled together and PVC jacketed., Outer Jacket Material: FR-PVC, Outer Diameter: 12.5mm nom., Weight: 240kg/km, Flamability Rating: IEC 60332-1
8A29004104 4x12 AWG XLPE 600V PVC Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, General Construction: 4-12 AWG XLPE insulated wires are cabled together and PVC jacketed., Outer Jacket Material: FR-PVC, Outer Diameter: 12.5mm nom., Weight: 240kg/km, Flamability Rating: IEC 60332-1
8A29005101 5x12 AWG XLPE Unshielded 600V Control Cable
Applications: Fixed or portable installation, Control and audio applications, Indoor, Applications: Control and audio applications, Indoor and outdoor use, General Construction: 5  -12 AWG XLPE insulated single cores, cabled concentrically and jacketed with a PVC compound., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 15.2mm nom., Weight: 320kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8A29006101 6x12 AWG XLPE 600V Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, General Construction: 6-12 AWG XLPE insulated wires,  cabled together and PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 15.5mm nom., Weight: 376kg/km, Flamability Rating: IEC 60332-1
8A29010101 10x12 AWG XLPE 600V PVC Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, General Construction: 10-12 AWG XLPE insulated wires are cabled together and PVC jacketed., Outer Jacket Material: FR-PVC, Outer Diameter: 20.1mm nom., Weight: 575kg/km, Flamability Rating: IEC 60332-1
8A29014101 14x12 AWG XLPE 600V PVC Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, General Construction: 14-12 AWG XLPE insulated wires are cabled together and PVC jacketed., Outer Jacket Material: FR-PVC, Outer Diameter: 21.4mm nom., Weight: 745kg/km, Flamability Rating: IEC 60332-1
8A29019101 19x12 AWG XLPE 600V PVC Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, General Construction: 19-12 AWG XLPE insulated wires are cabled together and PVC jacketed., Outer Jacket Material: FR-PVC, Outer Diameter: 24.6mm nom., Weight: 980kg/km, Flamability Rating: IEC 60332-1
8A29023101 23x12 AWG XLPE 600V PVC Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, General Construction: 23-12 AWG XLPE insulated wires are cabled together and PVC jacketed., Outer Jacket Material: FR-PVC, Outer Diameter: 26.8mm nom., Weight: 1190kg/km, Flamability Rating: IEC 60332-1
8A29027101 27x12 AWG XLPE 600V PVC Control Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Outdoor, General Construction: 27-12 AWG XLPE insulated wires are cabled together and PVC jacketed., Outer Jacket Material: FR-PVC, Outer Diameter: 29mm nom., Weight: 1380kg/km, Flamability Rating: IEC 60332-1

1 2 3 4 5 6 7 8 9 10 11 12 >>>>>|

Send to email Send selected products by email