8441001101 1x2x16 AWG XLPE Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 8.7mm nom., Weight: 92kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8551411101 1x2x14 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 11.0mm nom., Weight: 140kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8551601101 1x2x16 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 8.7mm nom., Weight: 90kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
85516C1103 1x2x16 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 8.7mm nom., Weight: 90kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8551801101 1x2x18 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 8.0mm nom., Weight: 75kg/km, Flamability Rating: IEC 60331
8552001101 1x2x20 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 7.5mm nom., Weight: 80kg/km, Flamability Rating: IEC 60331
8552501101 1x2x2.5 mm2 Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1-2.5 mm2 PVC insulated twisted pair, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 11mm nom., Weight: 140kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
85A1401101 1x2x14 AWG Direct Burial Instrumentation Cable Overall Shielded with Corrugated Steel Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier and corrugated steel armor (Rodent Protection) made of steel tape bonded to  FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 12.5mm nom., Weight: 200kg/km, Flamability Rating: IEC 60332-3 , UL 1581 VW-1
85A1601101 1x2x16 AWG Direct Burial Instrumentation Cable Overall Shielded with Corrugated Steel Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier and corrugated steel armor made of steel tape bonded to  FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 10.5mm nom., Weight: 130kg/km, Flamability Rating: IEC 60331
85A16B1101 1x2x16 AWG Overall Braid Shielded Direct Burial Instrumentation Cable with Corrugated Steel Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair is overall braid shielded and jacketed. A moisture barrier and corrugated steel armor made of steel tape bonded to an outer jacket complete the cable structure., Outer Jacket Material: FR-PE, Outer Diameter: 11.0mm nom., Weight: 180kg/km, Flamability Rating: IEC 60332-1
85A1801101 1x2x18 AWG Direct Burial Instrumentation Cable Overall Shielded with Corrugated Steel Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier and corrugated steel armor made of steel tape bonded to  FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 9.1mm nom., Weight: 122kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8651401101 1x3x14 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted triad, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 11.5mm nom., Weight: 170kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8651601101 1x3x16 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted triad, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 9.0mm nom., Weight: 115kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8651801101 1x3x18 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted triad, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 8.5mm nom., Weight: 90kg/km, Flamability Rating: IEC 60331
86A1601101 1x3x16 AWG Direct Burial Instrumentation Cable Overall Shielded with Corrugated Steel Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted triad, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier and corrugated steel armor made of steel tape bonded to  FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 10.5mm nom., Weight: 155kg/km, Flamability Rating: IEC 60331
8771416101 16x2x14 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 16 pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 31.5mm nom., Weight: 1230kg/km, Flamability Rating: IEC 60332-1
87714A2103 2x2x14 AWG Direct Burial Instrumentation Cable Overall shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 2 - Twisted pairs are cabled together with a communication wire and overall foil shielded. An inner jacket followed by a moisture barrier and an outer jacket complete the cable structure., Outer Jacket Material: FR-PE, Outer Diameter: 17.0mm nom., Weight: 295kg/km, Flamability Rating: IEC 60332-1
8771602101 2x2x16 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 2 pairs are cabled together with a communication wire, overall foil shielded and jacketed. A moisture barrier bonded to an outer jacket complete the cables structure., Outer Jacket Material: FR-PE, Outer Diameter: 15.5mm nom., Weight: 230kg/km, Flamability Rating: IEC 60332-1
8771602104 2x2x16 AWG Overall Shielded Instrumentation Cable with Moisture Barrier For Direct Burial
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 2 pairs are cabled together with a communication wire, overall foil shielded and jacketed. A moisture barrier bonded to an outer jacket complete the cables structure., Outer Jacket Material: FR-PE, Outer Diameter: 15.5mm nom., Weight: 230kg/km, Flamability Rating: IEC 60332-1
8771604101 4x2x16 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 4 pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 17.5mm nom., Weight: 325kg/km, Flamability Rating: IEC 60331
8771606101 6x2x16 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 6 pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 18.5mm nom., Weight: 390kg/km, Flamability Rating: IEC 60331
8771608101 8x2x16 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 8 pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 21.0mm nom., Weight: 505kg/km, Flamability Rating: IEC 60331
8771612101 12x2x16 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 12 pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 25.0mm nom., Weight: 720kg/km, Flamability Rating: IEC 60331
8771616101 16x2x16 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 16 pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 27.0mm nom., Weight: 890kg/km, Flamability Rating: IEC 60331
8771620101 20x2x16 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 20 pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 30.0mm nom., Weight: 1065kg/km, Flamability Rating: IEC 60331
8771802101 2x2x18 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 2 pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 13.5mm nom., Weight: 190kg/km, Flamability Rating: IEC 60331
8771804101 4x2x18 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 4 pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 15.0mm nom., Weight: 250kg/km, Flamability Rating: IEC 60331
8771808101 8x2x18 AWG Direct Burial Instrumentation Cable F/UTP with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 8 pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 18.0mm nom., Weight: 385kg/km, Flamability Rating: IEC 60331
8771816101 16x2x18 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 16 pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 24.5mm nom., Weight: 680kg/km, Flamability Rating: IEC 60331
8772002101 2x2x20 AWG Direct Burial Instrumentation Cable Overall Shielded with Moisture Barrier
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 2 pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier of aluminum tape bonded to outdoor FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 12.5mm nom., Weight: 150kg/km, Flamability Rating: IEC 60331