Instrumentation, Control & Signal  /  300V Shield+Armor

Filter Search Results By:

Conductors:
Standard:
Insulation Material:
 


Generic P/N Image Product Description PDF
8441201101 1x2x16 AWG XLPE Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  overall polyester/aluminum tape shielded pair, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 10.0mm nom., Weight: 225kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8561201101 1x2x12 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  overall polyester/aluminum tape shielded pair, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 13.5mm nom., Weight: 360kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8561401101 1x2x14 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  overall polyester/aluminum tape shielded pair, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 11.0mm nom., Weight: 245kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8561601101 1x2x16 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  overall polyester/aluminum tape shielded pair, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 10.0mm nom., Weight: 225kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8561801101 1x2x18 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: One twisted pair is shielded and jacketed. A served steel wire armor followed by an outer jacket completes the cable structure. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 9.5mm nom., Weight: 200kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8561801104 1x2x18 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: One twisted pair is shielded and jacketed. A served steel wire armor followed by an outer jacket completes the cable structure. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 9.5mm nom., Weight: 200kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8562001101 1x2x20 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 overall polyester/aluminum tape shielded pair, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 9.0mm nom., Weight: 175kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
85A1401101 1x2x14 AWG Direct Burial Instrumentation Cable Overall Shielded with Corrugated Steel Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier and corrugated steel armor (Rodent Protection) made of steel tape bonded to  FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 12.5mm nom., Weight: 200kg/km, Flamability Rating: IEC 60332-3 , UL 1581 VW-1
85A1601101 1x2x16 AWG Direct Burial Instrumentation Cable Overall Shielded with Corrugated Steel Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier and corrugated steel armor made of steel tape bonded to  FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 10.5mm nom., Weight: 130kg/km, Flamability Rating: IEC 60331
85A16B1101 1x2x16 AWG Overall Braid Shielded Direct Burial Instrumentation Cable with Corrugated Steel Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair is overall braid shielded and jacketed. A moisture barrier and corrugated steel armor made of steel tape bonded to an outer jacket complete the cable structure., Outer Jacket Material: FR-PE, Outer Diameter: 11.0mm nom., Weight: 180kg/km, Flamability Rating: IEC 60332-1
85A1801101 1x2x18 AWG Direct Burial Instrumentation Cable Overall Shielded with Corrugated Steel Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier and corrugated steel armor made of steel tape bonded to  FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 9.1mm nom., Weight: 122kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8661401101 1x3x14 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  triad overall polyester/aluminum tape shielded , inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 12.5mm nom., Weight: 335kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8661601101 1x3x16 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  overall polyester/aluminum tape shielded triad, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 10.5mm nom., Weight: 240kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8661801101 1x3x18 AWG Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  overall polyester/aluminum tape shielded triad, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 9.7mm nom., Weight: 205kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
86A1601101 1x3x16 AWG Direct Burial Instrumentation Cable Overall Shielded with Corrugated Steel Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted triad, overall polyester/aluminum tape shielded, inner PVC jacket, moisture barrier and corrugated steel armor made of steel tape bonded to  FR PE jacket., Outer Jacket Material: FR-PE, Outer Diameter: 10.5mm nom., Weight: 155kg/km, Flamability Rating: IEC 60331
8761206101 6x2x12 AWG Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 6  pairs are individual shielded with polyester/aluminum tape,  cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 29.0mm nom., Weight: 1590kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761402101 2x2x14 AWG Individual and Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Outdoor, Direct burial, Class 1 Division 2, General Construction: 2 - pairs are individually foil shielded,cabled together and overall foil shielded. An inner jacket followed by steel wire armor (rodent protection) and an outer jacket completes the cable structure., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 19.5mm nom., Weight: 690kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761405101 5x2x14 AWG Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 5 individualy shielded  pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 23.6mm nom., Weight: 1040kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761406101 6x2x14 AWG Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 6 individual shielded  pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 23.0mm nom., Weight: 1040kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761408101 8x2x14 AWG Individual and Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Outdoor, Direct burial, Class 1 Division 2, General Construction: 8 - pairs are individually foil shielded,cabled together and overall foil shielded. An inner jacket followed by steel wire armor (rodent protection) and an outer jacket completes the cable structure., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 27mm nom., Weight: 1515kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761412101 12x2x14 AWG Individual and Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Outdoor, Direct burial, Class 1 Division 2, General Construction: 12 - pairs are individually foil shielded,cabled together and overall foil shielded. An inner jacket followed by steel wire armor (rodent protection) and an outer jacket completes the cable structure., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 32.5mm nom., Weight: 1955kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761416101 16x2x14 AWG Individual and Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Outdoor, Direct burial, Class 1 Division 2, General Construction: 16 - pairs are individually foil shielded,cabled together and overall foil shielded. An inner jacket followed by steel wire armor (rodent protection) and an outer jacket completes the cable structure., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 36mm nom., Weight: 2380kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761424101 24x2x14 AWG Individual and Overall Shielded Armored Instrumentation Cable
Applications: Process control industry, Hazardous areas, Outdoor, Direct burial, Class 1 Division 2, General Construction: 24 Individually shielded twisted pairs are cabled together and overall foil shielded. An inner jacket followed by steel wire armor (rodent protection) and an outer jacket completes the cable structure., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 45.5mm nom., Weight: 3710kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761602101 2x2x16 AWG Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 2 individual shielded  pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 15.5mm nom., Weight: 450kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761603101 3x2x16 AWG Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 3 individual shielded  pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 16.5mm nom., Weight: 500kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761604101 4x2x16 AWG Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 4 individual shielded  pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 18.5mm nom., Weight: 695kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761605xxx 5x2x16 AWG Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 5 individually shielded  pairs are cabled together with a communication wire and overall foil shielded. An inner jacket followed by a served steel  wire  armor (Rodent Protection) and an outer jacket complete the cable structure. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 20.5mm nom., Weight: 800kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761606101 6x2x16 AWG Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 6 individual shielded  pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 21.0mm nom., Weight: 840kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761608101 8x2x16 AWG Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 8 individual shielded  pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 21.7mm nom., Weight: 970kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8761610101 10x2x16 AWG Individual and Overall Shielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 10 individual shielded  pairs are cabled together with a communication wire, overall polyester/aluminum tape shielded, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 26.0mm nom., Weight: 1245kg/km, Flamability Rating: IEC 60332-3 , IEEE 383

1 2 3 4 5 6 >>>>>|

Send to email Send selected products by email