Generic P/N Image Product Description PDF
8002206101 6x20 AWG Overall Shielded Control Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 6 single wires, cabled together with communication wire, overall polyester/aluminum foil shielded  and PVC jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 8.0mm nom., Weight: 95kg/km
8002208101 8x20 AWG Overall Shielded Control Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 8 single wires, cabled together with communication wire, overall polyester/aluminum foil shielded and PVC jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 9.0mm nom., Weight: 120kg/km
8002216101 16x20 AWG Overall Shielded Control Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 16 single wires, cabled together with communication wire, overall polyester/aluminum foil shielded and PVC jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 11.5mm nom., Weight: 195kg/km
8002308101 8x20 AWG Overall Shielded Control Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 8 single wires, cabled together with communication wire, overall polyester/aluminum foil shielded and PVC jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 9.0mm nom., Weight: 120kg/km
8002808101 8x20 AWG Overall Shielded Control Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 8 single wires, cabled together with communication wire, overall polyester/aluminum foil shielded and PVC jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 9.0mm nom., Weight: 120kg/km
8002816101 16x20 AWG Overall Shielded Control Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 16 single wires, cabled together with communication wire, overall polyester/aluminum foil shielded and PVC jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 11.5mm nom., Weight: 195kg/km
8296004101 4x18 AWG ETFE Insulated Overall Braid Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 4 wires are cabled together, overall copper braid shielded and PE jacketed., Outer Jacket Material: PE, Outer Diameter: 7.7mm nom., Weight: 85kg/km
8296201101 1x2x18 AWG ETFE Overall Shielded Instrumentation Cable (A-350)
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 1 twisted pair  overall polyester/aluminum tape shielded and  PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 6.5mm nom., Weight: 65kg/km
8296202101 2x2x18 AWG ETFE (Tefzel) Insulated Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 2 pairs are cabled together, overall polyester/aluminum tape shielded and PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 10.5mm nom., Weight: 120kg/km
8296204101 4x2x18 AWG ETFE (Tefzel) Insulated FTP Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Power stations, Outdoor, Class 1 Division 2, General Construction: 4 pairs are cabled together, overall polyester/aluminum tape shielded and PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 11.5mm nom., Weight: 180kg/km
8296207101 7x2x18 AWG ETFE (Tefzel) Insulated FTP Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Power stations, Outdoor, Class 1 Division 2, General Construction: 7 pairs are cabled together, overall polyester/aluminum tape shielded and PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 15mm nom., Weight: 275kg/km
8296212101 12x2x18 AWG ETFE (Tefzel) Insulated FTP Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Power stations, Outdoor, Class 1 Division 2, General Construction: 12 pairs are cabled together, overall polyester/aluminum tape shielded and PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 17.0mm nom., Weight: 435kg/km
8296224101 24x2x18 AWG ETFE (Tefzel) Insulated FTP Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Power stations, Outdoor, Class 1 Division 2, General Construction: 24 pairs are cabled together, overall polyester/aluminum tape shielded and PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 22.5mm nom., Weight: 780kg/km
8296301101 1x3x18 AWG ETFE Overall Shielded Instrumentation Cable (A-355)
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 1 triad  overall polyester/aluminum tape shielded and jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 7mm nom., Weight: 81kg/km
8297202101 2x2x18 AWG ETFE (Tefzel) Insulated U/FTP Instrumentation Cable
Applications: Process control industry, Hazardous areas, Power stations, Outdoor, Class 1 Division 2, General Construction: 2 twisted pairs,  individual polyester/aluminum tape shielded, cabled together and PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 10.5mm nom., Weight: 120kg/km
8297204101 4x2x18 AWG ETFE (Tefzel) Insulated U/FTP Instrumentation Cable
Applications: Process control industry, Hazardous areas, Power stations, Outdoor, Class 1 Division 2, General Construction: 4 twisted pairs,  individual polyester/aluminum tape shielded, cabled together and PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 12.5mm nom., Weight: 195kg/km
8297207101 7x2x18 AWG ETFE (Tefzel) Insulated U/FTP Instrumentation Cable
Applications: Process control industry, Hazardous areas, Power stations, Outdoor, Class 1 Division 2, General Construction: 7 twisted pairs,  individual polyester/aluminum tape shielded, cabled together and PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 15.5mm nom., Weight: 325kg/km
8298002101 1x2x16 AWG ETFE Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 1 twisted pair  overall polyester/aluminum tape shielded and  PVC jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 7.5mm nom., Weight: 85kg/km
8298003101 1x3x16 AWG ETFE Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 1 triad  overall polyester/aluminum tape shielded and jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 7.5mm nom., Weight: 102kg/km
8298402101 2x2x16 AWG ETFE Individual and Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 2 pairs are  individual polyester/aluminum tape shilded, cabled together with a communication wire, overall polyester/aluminum tape shielded and jacketed., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 11.3mm nom., Weight: 170kg/km
8441801101 1x2x16 AWG XLPE Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-PVC, Outer Diameter: 6.5mm nom., Weight: 67kg/km
8521211101 1x2x12 AWG Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-PVC, Outer Diameter: 8.8mm nom., Weight: 130kg/km
8521411101 1x2x14 AWG Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-PVC, Outer Diameter: 7.6mm nom., Weight: 92kg/km
8521601101 1x2x16 AWG Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, overall polyester/aluminum foil shielded and jacketed., Outer Jacket Material: FR-PVC, Outer Diameter: 5.7mm nom., Weight: 51kg/km
8521611101 1x2x16 AWG Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-PVC, Outer Diameter: 6.5mm nom., Weight: 62kg/km
8521621101 1x2x16 AWG Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-PVC, Outer Diameter: 7.3mm nom., Weight: 75kg/km
8521631101 1x2x16 AWG Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-PVC, Outer Diameter: 5.7mm nom., Weight: 51kg/km
8521681101 1x2x16 AWG Overall Shielded Instrumentation Cable With Double Jacket
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded and double FR PVC jacketed., Outer Jacket Material: FR-PVC, Outer Diameter: 7.3mm nom., Weight: 78kg/km
85216B1101 1x2x16 AWG SFTP Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, double shielded with  polyester/aluminum foil + TC braid and PVC jacketed., Outer Jacket Material: FR-PVC, Outer Diameter: 7.0mm nom., Weight: 82kg/km
8521801101 1x2x18 AWG Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded, Outer Jacket Material: FR-PVC, Outer Diameter: 5.0mm nom., Weight: 40.0kg/km