Home English  |  Русский  |  Español  |  Deutsch
User Name:
Password:
Why Register?
Forgotten Password?
Product Families
Computer & LAN
FiberOptics
Industrial Ethernet & BUS
Instrumentation, Control & Signal
Electronic & Audio
Telecom
Coax
Power
Military & Defense
Specialty Cables
Product Search:
Advanced Search


SITE SEARCH
Instrumentation, Control & Signal  /  300V

Filter Search Results By:

Conductors:
Standard:
Insulation Material:
 


Generic P/N Image Product Description PDF
3361412xxx 12x14 AWG Speacker and Control Cable FPLR
Applications: Fire alarm, Indoor, General Construction: 12 PVC insulated wires, cabled together and jacketed with PVC riser grade., Outer Jacket Material: FR-PVC, Outer Diameter: 16.5mm nom., Weight: 450kg/km, Flamability Rating: IEC 60332-3 , IEEE 383, UL CMR
4163470xxx 1.63/4.7 14 AWG PVC Insulated Outdoor Control Wire
Applications: Indoor, Outdoor, Applications: , General Construction: 14 AWG, solid, PVC insulate wire., Outer Jacket Material: FR-PVC, Outer Diameter: 4.7mm nom., Weight: 41kg/km, Flamability Rating: IEC 60332-1
7001626104 26x16 AWG Multicore Unshielded Control Cable
Applications: Indoor and outdoor, Control applications, General Construction: 26 single cores, cabled concentrically and jacketed with a UV resistant  PVC, Outer Jacket Material: FR-PVC, Outer Diameter: 12.5mm nom., Weight: 400kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
708MB20101 20x18 AWG 300V Unshielded Control Cable with Moisture Barrier
Applications: Process control industry, Hazardous areas, Direct burial, Class 1 Division 2, General Construction: 20 Insulated wires are cabled together and jacketed. A Moisture Barrier of aluminum tape followed by an outer jacket complete the cable structure., Outer Jacket Material: FR-PE, Outer Diameter: 18.0mm nom., Weight: 420kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8002218101 18x20 AWG Unshielded Control Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 18 single wires ( 16 White numbered and 2 Black, cabled together and PVC jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 11.5mm nom., Weight: 205kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8298B02101 2x2x16 AWG ETFE Cable with XL-HFFR Jacket
Applications: Audio-frequency signals, Indoor and outdoor, Control applications, Applications: Process control industry, Hazardous areas, Short-range low-frequency signals, Fire alarm, Harsh environments, Indoor, Outdoor, General Construction: 2 ETFE insulated twisted pairs, cabled together and jacketed with a  XL-HFFR compound. The cable has excelent abrassion and chemical resistance., Outer Jacket Material: XL-HFFR, Outer Diameter: 10.5mm nom., Weight: 135kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8298M02101 2x2x16 AWG ETFE Cable with XL-HFFR Jacket
Applications: Audio-frequency signals, Indoor and outdoor, Control applications, Applications: Process control industry, Hazardous areas, Short-range low-frequency signals, Fire alarm, Harsh environments, Indoor, Outdoor, General Construction: 2 ETFE insulated twisted pairs, cabled together and jacketed with a  XL-HFFR compound. The cable has excelent abrassion and chemical resistance., Outer Jacket Material: XL-HFFR, Outer Diameter: 11.5mm nom., Weight: 155kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8501002101 2x10 AWG Unshielded Control Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 12.5mm nom., Weight: 200kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8501201101 1x2x12 AWG Unshielded Control Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 9.0mm nom., Weight: 115kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8501202101 2x2x12 AWG unshielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 2  pairs are cabled together with a communication wire and jacketed with a PVC compound ., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 15.5mm nom., Weight: 280kg/km, Flamability Rating: IEC 60332-1
8501401103 2x14 AWG Unshielded Fire Alarm and Control Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 7.5mm nom., Weight: 77kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8501401xxx 2x14 AWG Unshielded Control Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 7.5mm nom., Weight: 77kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8501402101 2x2x14 AWG Unshielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 2 Unshielded twisted pairs are cabled together and jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 13.0mm nom., Weight: 170kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8501601101 2x16 AWG Unshielded Control Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 5.6mm nom., Weight: 45kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8501601103 2x16 AWG Unshielded Control Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair is jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 5.6mm nom., Weight: 45kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8501602101 2x2x16 AWG unshielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 2  pairs are cabled together with a communication wire and jacketed with a PVC compound ., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 9.6mm nom., Weight: 125kg/km, Flamability Rating: IEC 60332-1
8501604101 4x2x16 AWG Unshielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, General Construction: 4 pairs are cabled together and  PVC jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 13.5mm nom., Weight: 215kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
85016A1101 1x2x16 AWG Unshielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  twisted pair with inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 11.0mm nom., Weight: 235kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8501801101 2x18 AWG Unshielded Control Cable
Applications: Process control industry, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 5.8mm nom., Weight: 45kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8501805101 5x2x18 AWG Unshielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, General Construction: 5 pairs are cabled together  and jacketed with PVC., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 12.2mm nom., Weight: 180kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8501806101 6x2x18 AWG unshielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 6 pairs are cabled together with a communication wire and jacketed with a PVC compound ., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 12.6mm nom., Weight: 210kg/km, Flamability Rating: IEC 60332-1
8501808101 8x2x18 AWG unshielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 8  pairs are cabled together with a communication wire and jacketed with a PVC compound ., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 17.1mm nom., Weight: 280kg/km, Flamability Rating: IEC 60332-1
8501836101 36x2x18 AWG unshielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 36 pairs are cabled together with a communication wire and jacketed with a PVC compound ., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 25.5mm nom., Weight: 1015kg/km, Flamability Rating: IEC 60332-1
8502001101 2x20 AWG Unshielded Control Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 5.0mm nom., Weight: 30kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8502003101 3x2x20 AWG Unshielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, General Construction: 3 pairs are cabled together  and jacketed with PVC., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 9.2mm nom., Weight: 100kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8502005101 5x2x20 AWG Unshielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, General Construction: 5 pairs are cabled together  and jacketed with PVC., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 11.0mm nom., Weight: 140kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
85020C1101 2x20 AWG Unshielded Control Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 5.3mm nom., Weight: 35kg/km, Flamability Rating: IEC 60332-3 , IEEE 383
8521211101 1x2x12 AWG Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-PVC, Outer Diameter: 8.8mm nom., Weight: 130kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8521211103 1x2x12 AWG Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 1 twisted pair is cabled together with a drain-wire and overall foil shielded and jacketed., Outer Jacket Material: FR-PVC, Outer Diameter: 8.8mm nom., Weight: 130kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1
8521411101 1x2x14 AWG Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-PVC, Outer Diameter: 7.6mm nom., Weight: 92kg/km, Flamability Rating: IEC 60332-1, UL 1581 VW-1

1 2 3 4 >>>>>|

Send to email Send selected products by email