Generic P/N |
Image |
Product Description |
PDF |
|
|
7001626104
|
 |
26x16 AWG Multicore Unshielded Control Cable |
|
| Applications: Indoor and outdoor, Control applications, General Construction: 26 single cores, cabled concentrically and jacketed with a UV resistant PVC, Outer Jacket Material: FR-PVC, Outer Diameter: 12.5mm nom., Weight: 400kg/km |
|
|
8002218101
|
 |
18x20 AWG Unshielded Control Cable |
|
| Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 18 single wires ( 16 White numbered and 2 Black, cabled together and PVC jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 11.5mm nom., Weight: 205kg/km |
|
|
8501002101
|
 |
2x10 AWG Unshielded Control Cable |
|
| Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 12.5mm nom., Weight: 200kg/km |
|
|
8501202101
|
 |
2x12 AWG Unshielded Control Cable |
|
| Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 9.0mm nom., Weight: 115kg/km |
|
|
8501401103
|
 |
2x14 AWG Unshielded Fire Alarm and Control Cable |
|
| Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 7.5mm nom., Weight: 77kg/km |
|
|
8501401xxx
|
 |
2x14 AWG Unshielded Control Cable |
|
| Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 7.5mm nom., Weight: 77kg/km |
|
|
8501601101
|
 |
2x16 AWG Unshielded Control Cable |
|
| Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 5.6mm nom., Weight: 45kg/km |
|
|
8501604101
|
 |
4x2x16 AWG Unshielded Instrumentation Cable |
|
| Applications: Process control industry, Hazardous areas, General Construction: 4 pairs are cabled together and PVC jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 13.5mm nom., Weight: 215kg/km |
|
|
85016A1101
|
 |
1x2x16 AWG Unshielded Instrumentation Cable with Served Wire Armor |
|
| Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair with inner PVC jacket, served steel wire armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 11.0mm nom., Weight: 235kg/km |
|
|
8501801101
|
 |
2x18 AWG Unshielded Control Cable |
|
| Applications: Process control industry, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 5.8mm nom., Weight: 45kg/km |
|
|
8501805101
|
 |
5x2x18 AWG Unshielded Instrumentation Cable |
|
| Applications: Process control industry, Hazardous areas, General Construction: 5 pairs are cabled together and jacketed with PVC., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 12.2mm nom., Weight: 180kg/km |
|
|
8502001101
|
 |
2x20 AWG Unshielded Control Cable |
|
| Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 5.0mm nom., Weight: 30kg/km |
|
|
8502005101
|
 |
5x2x20 AWG Unshielded Instrumentation Cable |
|
| Applications: Process control industry, Hazardous areas, General Construction: 5 pairs are cabled together and jacketed with PVC., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 11.0mm nom., Weight: 140kg/km |
|
|
8521211101
|
 |
1x2x12 AWG Overall Shielded Instrumentation Cable |
|
| Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-PVC, Outer Diameter: 8.8mm nom., Weight: 130kg/km |
|
|
8521411101
|
 |
1x2x14 AWG Overall Shielded Instrumentation Cable |
|
| Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-PVC, Outer Diameter: 7.6mm nom., Weight: 92kg/km |
|
|
8522501101
|
 |
1x2x2.5 mm2 Overall Shielded Instrumentation Cable |
|
| Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One 2.5 mm2 PVC insulated twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-PVC, Outer Diameter: 8mm nom., Weight: 95kg/km |
|
|
86016A1101
|
 |
1x3x16 AWG Unshielded Instrumentation Cable with Served Wire Armor |
|
| Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, General Construction: 1 twisted triad with inner PVC jacket, served steel wire armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 11.2mm nom., Weight: 243kg/km |
|
|
8802002101
|
 |
2x3x20 AWG Overall Shielded Instrumentation Cable |
|
| Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 2 triads are cabled together with a communication wire, overall polyester/aluminum tape shielded and jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 10.2mm nom., Weight: 115kg/km |
|
|
8N21P01xxx
|
 |
1x2x12 AWG Overall Shielded FPLR Fire Alarm and Control Cable |
|
| Applications: Hazardous areas, Fire alarm, Indoor, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded and jacketed with FRPVC, riser grade., Outer Jacket Material: FR-PVC, Outer Diameter: 9.5mm nom., Weight: 145kg/km |
|
|
8N41601103
|
 |
1x2x14 AWG Overall Shielded Instrumentation Cable with HFFR Jacket |
|
| Applications: Short-range low-frequency signals, Fire alarm, Indoor, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shieldedand HFFR jacketed., Outer Jacket Material: HFFR, Outer Diameter: 7.6mm nom., Weight: 94kg/km |
|
|
8N41P01xxx
|
 |
1x2x14 AWG Overall Shielded FPLR Fire Alarm and Control Cable |
|
| Applications: Hazardous areas, Fire alarm, Indoor, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded and jacketed with FRPVC, riser grade., Outer Jacket Material: FR-PVC, Outer Diameter: 8.2mm nom., Weight: 105kg/km |
|
|
8N4S101101
|
 |
1x2x14 AWG Unshielded Instrumentation Cable with Served Wire Armor |
|
| Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 -14 AWG unshielded pair, inner PVC jacket, served steel wire armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 12.5mm nom., Weight: 320kg/km |
|
|
8N4S112101
|
 |
12x2x14 AWG Unshielded Instrumentation Cable with Served Wire Armor |
|
| Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 12 -14 AWG unshielded pairs, inner PVC jacket, served steel wire armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 26.0mm nom., Weight: 1430kg/km |
|
|
8N4V124101
|
 |
24x14 AWG Unshielded Instrumentation Cable with Served Wire Armor |
|
| Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 24 wires are cabled together, inner PVC jacket, served steel wire armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 26.0mm nom., Weight: 1400kg/km |
|
|
8N60601101
|
 |
2x16 AWG Unshielded Control Cable with HFFR Jacket |
|
| Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 16 AWG twisted pair with HFFR jacket., Outer Jacket Material: HFFR, Outer Diameter: 5.6mm nom., Weight: 42kg/km |
|
|
8N6S001101
|
 |
1x2x16 AWG Unshielded Instrumentation Cable with Served Wire Armor |
|
| Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1 twisted pair with inner PVC jacket, served steel wire armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 11.0mm nom., Weight: 235kg/km |
|
|
8NR5001101
|
 |
3x14 AWG Unshielded Control Cable |
|
| Applications: Process control industry, Short-range low-frequency signals, Indoor, Outdoor, General Construction: 1 twisted triad with PVC jacket., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 8.0mm nom., Weight: 105kg/km |
|
|
8NR501xxx
|
 |
1x3x14 AWG Control Cable |
|
| Applications: Short-range low-frequency signals, Indoor, Outdoor, General Construction: One twisted triad with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 8.0mm nom., Weight: 105kg/km |
|
|
8S41601101
|
 |
1x2x14 AWG Overall Shielded Instrumentation FR-LSZH Cable |
|
| Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-LSZH, Outer Diameter: 7.6mm nom., Weight: 92kg/km |
|
|
8S99606101
|
 |
6x20 AWG 300 V Unshielded HFFR Instrumentation Cable |
|
| Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Class 1 Division 2, General Construction: Low Smoke, HFFR instrumentation and control cable, designed for process control industry., Outer Jacket Material: HFFR, Outer Diameter: 7.0mm nom., Weight: 70kg/km |