Instrumentation, Control & Signal  /  300V

Filter Search Results By:

Conductors:
Standard:
Insulation Material:
 


Generic P/N Image Product Description PDF
7001626104 26x16 AWG Multicore Unshielded Control Cable
Applications: Indoor and outdoor, Control applications, General Construction: 26 single cores, cabled concentrically and jacketed with a UV resistant  PVC, Outer Jacket Material: FR-PVC, Outer Diameter: 12.5mm nom., Weight: 400kg/km
8002218101 18x20 AWG Unshielded Control Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 18 single wires ( 16 White numbered and 2 Black, cabled together and PVC jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 11.5mm nom., Weight: 205kg/km
8501002101 2x10 AWG Unshielded Control Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 12.5mm nom., Weight: 200kg/km
8501202101 2x12 AWG Unshielded Control Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 9.0mm nom., Weight: 115kg/km
8501401103 2x14 AWG Unshielded Fire Alarm and Control Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 7.5mm nom., Weight: 77kg/km
8501401xxx 2x14 AWG Unshielded Control Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 7.5mm nom., Weight: 77kg/km
8501601101 2x16 AWG Unshielded Control Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 5.6mm nom., Weight: 45kg/km
8501604101 4x2x16 AWG Unshielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, General Construction: 4 pairs are cabled together and  PVC jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 13.5mm nom., Weight: 215kg/km
85016A1101 1x2x16 AWG Unshielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  twisted pair with inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 11.0mm nom., Weight: 235kg/km
8501801101 2x18 AWG Unshielded Control Cable
Applications: Process control industry, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 5.8mm nom., Weight: 45kg/km
8501805101 5x2x18 AWG Unshielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, General Construction: 5 pairs are cabled together  and jacketed with PVC., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 12.2mm nom., Weight: 180kg/km
8502001101 2x20 AWG Unshielded Control Cable
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 twisted pair with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 5.0mm nom., Weight: 30kg/km
8502005101 5x2x20 AWG Unshielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, General Construction: 5 pairs are cabled together  and jacketed with PVC., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 11.0mm nom., Weight: 140kg/km
8521211101 1x2x12 AWG Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-PVC, Outer Diameter: 8.8mm nom., Weight: 130kg/km
8521411101 1x2x14 AWG Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-PVC, Outer Diameter: 7.6mm nom., Weight: 92kg/km
8522501101 1x2x2.5 mm2 Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One 2.5 mm2 PVC insulated twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-PVC, Outer Diameter: 8mm nom., Weight: 95kg/km
86016A1101 1x3x16 AWG Unshielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, General Construction: 1  twisted triad with inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 11.2mm nom., Weight: 243kg/km
8802002101 2x3x20 AWG Overall Shielded Instrumentation Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: 2 triads are cabled together with a communication wire, overall polyester/aluminum tape shielded and jacketed., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 10.2mm nom., Weight: 115kg/km
8N21P01xxx 1x2x12 AWG Overall Shielded FPLR Fire Alarm and Control Cable
Applications: Hazardous areas, Fire alarm, Indoor, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded and jacketed with FRPVC, riser grade., Outer Jacket Material: FR-PVC, Outer Diameter: 9.5mm nom., Weight: 145kg/km
8N41601103 1x2x14 AWG Overall Shielded Instrumentation Cable with HFFR Jacket
Applications: Short-range low-frequency signals, Fire alarm, Indoor, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shieldedand HFFR jacketed., Outer Jacket Material: HFFR, Outer Diameter: 7.6mm nom., Weight: 94kg/km
8N41P01xxx 1x2x14 AWG Overall Shielded FPLR Fire Alarm and Control Cable
Applications: Hazardous areas, Fire alarm, Indoor, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded and jacketed with FRPVC, riser grade., Outer Jacket Material: FR-PVC, Outer Diameter: 8.2mm nom., Weight: 105kg/km
8N4S101101 1x2x14 AWG Unshielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  -14 AWG unshielded pair, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 12.5mm nom., Weight: 320kg/km
8N4S112101 12x2x14 AWG Unshielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 12  -14 AWG unshielded pairs, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC, Outer Diameter: 26.0mm nom., Weight: 1430kg/km
8N4V124101 24x14 AWG Unshielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 24 wires are cabled together, inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 26.0mm nom., Weight: 1400kg/km
8N60601101 2x16 AWG Unshielded Control Cable with HFFR Jacket
Applications: Process control industry, Hazardous areas, Indoor, Outdoor, General Construction: 1 16 AWG twisted pair with HFFR jacket., Outer Jacket Material: HFFR, Outer Diameter: 5.6mm nom., Weight: 42kg/km
8N6S001101 1x2x16 AWG Unshielded Instrumentation Cable with Served Wire Armor
Applications: Process control industry, Hazardous areas, Harsh environments, Direct burial, Class 1 Division 2, General Construction: 1  twisted pair with inner PVC jacket, served steel  wire  armor (Rodent Protection) and outer PVC jacket. , Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 11.0mm nom., Weight: 235kg/km
8NR5001101 3x14 AWG Unshielded Control Cable
Applications: Process control industry, Short-range low-frequency signals, Indoor, Outdoor, General Construction: 1 twisted triad with PVC jacket., Outer Jacket Material: FR-PVC ST2 per IEC 60502, Outer Diameter: 8.0mm nom., Weight: 105kg/km
8NR501xxx 1x3x14 AWG Control Cable
Applications: Short-range low-frequency signals, Indoor, Outdoor, General Construction: One twisted triad with PVC jacket., Outer Jacket Material: UV resistant FR-PVC, Outer Diameter: 8.0mm nom., Weight: 105kg/km
8S41601101 1x2x14 AWG Overall Shielded Instrumentation FR-LSZH Cable
Applications: Process control industry, Hazardous areas, Class 1 Division 2, General Construction: One twisted pair, cabled together with a drain-wire and overall aluminum-foil shielded., Outer Jacket Material: FR-LSZH, Outer Diameter: 7.6mm nom., Weight: 92kg/km
8S99606101 6x20 AWG 300 V Unshielded HFFR Instrumentation Cable
Applications: Process control industry, Hazardous areas, Harsh environments, Indoor, Outdoor, Class 1 Division 2, General Construction: Low Smoke, HFFR instrumentation and control cable, designed for process control industry., Outer Jacket Material: HFFR, Outer Diameter: 7.0mm nom., Weight: 70kg/km

1 2 >>>>>|